Tds4 2, Exp(-t – C&H Technology TDS4__4002 User Manual

Page 4

Advertising
background image

TDS4__4002

Phase Control Thyristor

Powerex, Inc., 173 Pavilion Ln, Youngwood, PA 15697 www.pwrx.com (724)925-7272

4000Amperes 3000Volts

Electrical Characteristics,

Tj=25°C unless otherwise specified

Rating

Characteristic

Symbol

Test Conditions

min

typ

max

Units

Repetitive Peak Forward

Leakage Current

I

DRM

Tj=125°C, V

DRM

=Rated

250

ma

Repetitive Peak Reverse

Leakage Current

I

RRM

Tj=125°C, V

RRM

=Rated

250

ma

Peak On-State Voltage

V

TM

Tj=125°C, I

TM

=4000A

1.38

V

V

TM

Model, Low Level

V

0

Tj=125°C

0.942

V

VTM = V

O

+

r•

I

TM

r

15%

I

TM

- π•I

TM

9.79E-02

mΩ

V

TM

Model, High Level

V

0

Tj=125°C

1.175

V

VTM = V

O

+

r•

I

TM

r

π•I

TM

- I

TSM

7.45E-02

mΩ

V

TM

Model, 4-Term

A

Tj=125°C

-0.257

V

TM

= A + B•Ln(I

TM

) +

B

15%I

TM

- I

TSM

0.185

C•(I

TM

) + D•(I

TM

)

½

C

7.73E-05

D

-3.20E-03

Turn-On Delay Time

t

d

V

D

= 0.5•V

DRM

3

us

Gate Drive: 40V - 20Ω

T rn Off Time

tq

Tj 125°C

600

s

Turn-Off Time

tq

Tj=125°C

600

us

dv/dt = 20V/us to 67% V

DRM

dv/dt

(Crit)

dv/dt

Tj=125°C Exp. Waveform

800

V/us

V

D

=67% Rated

Gate Trigger Current

I

GT

Tj=25°C V

D

= 12V

30

150

300

ma

Gate Trigger Voltage

V

GT

0.8

2.0

5.0

V

Peak Reverse Gate Voltage

V

GRM

5

V

Reverse Recovery Currrent

IR(Rec) Tj=125°C V

R

= 100V

300

A

Reverse Recovery Charge

QRA

10,500

µCoul

Thermal Characteristics

Rating

Characteristic

Symbol

Test Conditions

min

typ

max

Units

Thermal Resistance

Junction to Case

jc

Double side cooled

0.0065

0.0070

°C/Watt

Case to Sink

cs

Double side cooled

0.001

0.0015

°C/Watt

Thermal Impedance Model

jc

Double side cooled

jc

(t) =

Σ(A(

N

)•(1-exp(-t/

Tau

(

N

))))

where:

N =

1

2

3

4

A(N

) =

1.43E-04

9.08E-04

2.37E-03

3.50E-03

T

au(N) =

2.62E-03

2.31E-02

3.05E-01

3.60E+00

Page 3 of 5

Advertising