PS51789
Intellimod™ Module
Dual-In-Line Intelligent Power Factor Correction Module
30 Amperes/600 Volts

2

03/10 Rev. 0

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com

Absolute Maximum Ratings, T

j

= 25°C unless otherwise specified

Characteristics

Symbol

PS51789

Units

Input Supply Voltage (Between S-R Terminals)

V

i

264

V

rms

Input Supply Voltage, Surge (Between S-R Terminals)

V

i(surge)

500

Volts

Output Voltage (Between P-N Terminals)

V

O

450

Volts

Output Voltage, Surge (Between P-N Terminals)

V

O(surge)

500

Volts

Collector-Emitter Voltage

V

CES

600

Volts

Repetative Peak Reverse Voltage

V

RRM

600

Volts

Input Current, 100% Load (T

C

≤ 100°C, V

i

= 220V

rms

, V

O

= 390V, f

PWM

= 20kHz)

I

i

30

A

rms

Input Current, 125% Load (T

C

≤ 100°C, V

i

= 220V

rms

, V

O

= 390V,

I

i(125%)

37.5

A

rms

f

PWM

= 20kHz, Non-repetative, within 1 Minute)

I

2

t for Fusing (Value for 1 Cycle of Surge Current, tw = 8.3ms)

I

2

t

270

A

2

s

Junction Temperature*

T

j

-20 to 150

°C

Module Case Operation Temperature

T

C

-20 to 100

°C

Storage Temperature

T

stg

-40 to 125

°C

Mounting Torque, M3 Mounting Screws

8.7

in-lb

Module Weight (Typical)

21

Grams

Isolation Voltage, AC 1 minute, 60Hz Sinusoidal, Connection Pins to Heatsink Plate

V

ISO

2500

V

rms

Control Sector

Control Supply Voltage (Applied between V

D

-GND)

V

D

20

Volts

Input Voltage (Applied between V

IN

-GND)

V

IN

0 ~ V

D

+0.5

Volts

Fault Output Supply Voltage (Applied between F

O

-V

NC

)

V

FO

-0.5 ~ V

D

+0.5

Volts

Fault Output Current (Sink Current at F

O

Terminal)

I

FO

1

mA

Current Sensing Input Voltage (Applied between C

IN

-V

NC

)

V

SC

-0.5 ~ V

D

+0.5

Volts

*The maximum junction temperature rating of the power chips integrated within the DIPPFC is 150°C (@T

C

≤ 100°C). However, to ensure safe operation of the DIPPFC,

the average junction temperature should be limited to T

j(avg)

≤ 125°C (@T

C

≤ 100°C).

T

C

Measurement Point

4.6 mm

25.4mm

IGBT

CONTROL TERMINALS

POWER TERMINALS

T

C

POINT

Advertising