C&H Technology PM800HSA120 User Manual

Page 5

Advertising
background image

PM800HSA120
Intellimod™ Module
Half Phase IGBT Inverter Output
800 Amperes/1200 Volts

4

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

Electrical and Mechanical Characteristics,

T

j

= 25°C unless otherwise specified

Characteristics

Symbol

Test Conditions

Min.

Typ.

Max.

Units

IGBT Inverter Sector

Collector Cutoff Current

I

CES

V

CE

= V

CES

, T

j

= 25

°

C

1.0

mA

V

CE

= V

CES

, T

j

= 125

°

C

10

mA

Diode Forward Voltage

V

FM

-I

C

= 800A, V

D

= 15V, V

CIN

= 5V

2.

5

3.5

Volts

Collector-Emitter Saturation Voltage

V

CE(sat)

V

D

= 15V, V

CIN

= 0V, I

C

= 800A,

2.5

3.5

Volts

T

j

= 25

°

C

V

D

= 15V, V

CIN

= 0V, I

C

= 800A,

2.3

3.

0

Volts

T

j

= 125

°

C

Inductive Load Switching Times

t

on

0.5

1.4

2.5

µ

S

t

rr

V

D

= 15V, V

CIN

= 0 ~ 5V

0.2

0.4

µ

S

t

C(on)

V

CC

= 600V, I

C

= 800A

0.4

1.0

µ

S

t

off

T

j

= 125

°

C

2.5

4.0

µS

t

C(off)

0.6

1.

2

µ

S

Thermal Characteristics

Characteristic

Symbol

Condition

Min.

Typ.

Max.

Units

Junction to Case Thermal Resistance

R

th(j-c)Q

Each IGBT

0.027

°

C/Watt

R

th(j-c)D

Each FWDi

0.045

°

C/Watt

Contact Thermal Resistance

R

th(c-f)

Case to Fin Per Module,

0.022

°

C/Watt

Thermal Grease Applied

Recommended Conditions for Use

Characteristic

Symbol

Condition

Value

Units

Supply Voltage

V

CC

Applied across C1-E2 Terminals

0 ~ 800

Volts

V

D

Applied between V

1

-V

C

15

±

1.5

Volts

Input ON Voltage

V

CIN(on)

Applied between C

1

-V

C

0 ~ 0.8

Volts

Input OFF Voltage

V

CIN(off)

Applied between C

1

-V

C

4.0 ~ V

SXR

Volts

PWM Input Frequency

f

PWM

Using Application Circuit

5 ~ 20

kHz

Minimum Dead Time

t

DEAD

Input Signal

4.0

µ

S

Advertising