PS21765
Intellimod™ Module
Dual-In-Line Intelligent Power Module
20 Amperes/600 Volts

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272



Rev. 07/07

Thermal Characteristics

Characteristic

Symbol

Condition

Min.

Typ.

Max.

Units

Junction to Case

R

th(j-c)Q

Inverter IGBT (Per 1/6 Module)

1.3

°C/Watt

R

th(j-c)D

Inverter FWDi (Per 1/6 Module)

3.0

°C/Watt

Recommended Conditions for Use

Characteristic

Symbol

Condition

Min.

Typ.

Value

Units

Supply Voltage

V

CC

Applied between P-N

U

, N

V

, N

W

0

300

400

Volts

Control Supply Voltage

V

D

Applied between V

P1

-V

NC

, V

N1

-V

NC

13.5

15.0

16.5

Volts

V

DB

Applied between V

UFB

-V

UFS

,

13.0

15.0

18.5

Volts

V

VFB

-V

VFS

, V

WFB

-V

WFS

Control Supply Variation

dV

D

, dV

DB

-1

1

V/µs

Arm Shoot-through

t

DEAD

For Each Input Signal,

2.0

µs

Blocking Time

T

C

≤ 100°C

PWM Input Frequency

f

PWM

T

C

≤ 100°C, T

j

≤ 125°C

20

kHz

Allowable Minimum

P

WIN(on)

**

0.3

µs

Input Pulse Width

P

WIN(off)

***

Below Rated

200V

≤ V

CC

≤ 350V,

1.4

µs

Current

13.5V

≤ V

D

≤ 16.5V,

Between Rated

13.0V

≤ V

DB

≤ 18.5V,

2.5

µs

Current and 1.7

-20°C

≤ T

C

≤ 100°C, N-line

Times Rated Current Wiring Inductance < 10nH

V

NC

Voltage Variation

V

NC

Between V

NC

-N

U

, N

V

, N

W

,

-5.0

5.0

Volts

(Including Surge)

Junction Temperature

T

j

-20

125

°C

*The allowable RMS current value depends on the actual application conditions.
**The input signal with ON pulse less than P

WIN(on)

may make no response.

***DIP-IPM may make a delayed response (less than about 2µsec) or no response for the input signal with OFF pulse width less than P

WIN(off)

. Refer to About Delayed Response Against

Shorter Input OFF Signal than P

WIN(off

(P-side Only) and Recommended Wiring Around the Shunt Resistor for detals about N-line inductance.

Delayed Response Against Shorter Input OFF Signal than P

WIN(off)

(P-side Only)

t2

t1

P-SIDE

CONTROL INPUT

INTERNAL

IGBT GATE

OUTPUT

CURRENT IC

Solid Line – OFF Pulse Width > PWIN(off): Turn ON time t1.