PM25RLA120
Intellimod™ L-Series
Three Phase IGBT Inverter + Brake
25 Amperes/1200 Volts

Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

V

CC

= 600V

V

D

= 15V

T

j

= 25°C

T

j

= 125°C

V

CC

= 600V

V

D

= 15V

T

j

= 25°C

T

j

= 125°C

COLLECTOR CURRENT, -I

C

, (AMPERES)

REVERSE RECO

VER

Y CURRENT

, I

rr

, (AMPERES)

REVERSE RECOVERY TIME,

t

rr

, (s

)

10

2

10

0

10

1

10

1

10

0

10

2

10

0

10

0

10

1

10

-1

10

-2

10

2

COLLECTOR CURRENT, -I

C

, (AMPERES)

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING LOSS,

E

SW(on)

, (mJ/PULSE)

10

1

10

0

10

0

10

1

10

-1

10

2

10

1

10

0

10

0

10

1

10

-1

10

2

SWITCHING LOSS (ON) VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART)

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING LOSS,

E

SW(o

ff)

, (mJ/PULSE)

SWITCHING LOSS (OFF) VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART)

REVERSE RECOVERY CHARACTERISTICS

(TYPICAL - INVERTER PART)

EMITTER-COLLECTOR VOLTAGE, V

EC

, (VOLTS)

COLLECTOR CURRENT, -I

C

, (AMPERES)

FREE-WHEEL DIODE

FORWARD CHARACTERISTICS

(TYPICAL - INVERTER PART)

0

2.0

2.5

1.5

1.0

0.5

10

2

10

1

10

0

V

D

= 15V

T

j

= 25°C

T

j

= 125°C

REVERSE RECOVERY CHARACTERISTICS

(TYPICAL - INVERTER PART)

10

0

10

1

10

2

10

-1

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIMES,

t

on

, (

µs)

SWITCHING TIME VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART)

10

0

10

1

V

CC

= 600V

V

D

= 15V

T

j

= 25

o

C

T

j

= 125

o

C

INDUCTIVE LOAD

V

CC

= 600V

V

D

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD

INDUCTIVE LOAD

V

CC

= 600V

V

D

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD

INDUCTIVE LOAD

PM25RLA120_4_12.eps

10

0

10

1

10

2

10

-1

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIMES

, t

c(on)

, (

µs)

SWITCHING TIME VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART)

10

0

10

1

V

CC

= 600V

V

D

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD

10

0

10

1

10

2

10

-1

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIMES

, t

c(off)

, (

µs)

SWITCHING TIME VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART)

10

0

10

1

V

CC

= 600V

V

D

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD

10

0

10

1

10

2

10

-1

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIMES

, t

of

f

, (

µs)

SWITCHING TIME VS.

COLLECTOR CURRENT

(TYPICAL - INVERTER PART)

10

0

10

1

V

CC

= 600V

V

D

= 15V

T

j

= 25°C

T

j

= 125°C

INDUCTIVE LOAD

Advertising