Cd43 b, Pow-r-blok, Electrical characteristics, t – C&H Technology CD43__40B User Manual

Page 4: 25°c unless otherwise specified, Thermal characteristics

Advertising
background image


Powerex, Inc., Hillis Street, Youngwood, Pennsylvania 15697 (724) 925-7272

POW-R-BLOK

TM

Dual SCR Isolated Module

40 Amperes / Up to 1800 Volts

Revision Date: 04/28/2009

CD43__40B




Electrical Characteristics, T

J

=25°C unless otherwise specified

Characteristics Symbol

Test

Conditions

Min.

Max.

Units

Repetitive Peak Forward Leakage Current

I

DRM

Up to 1800V, T

J

=125°C

20

mA

Repetitive Peak Reverse Leakage Current

I

RRM

Up to 1800V, T

J

=125°C

20

mA

Peak On-State Voltage

V

FM

I

TM

=200A

1.95

V

Threshold Voltage, Low-level
Slope Resistance, Low-level

V

(TO)1

r

T1

T

J

= 125°C, I = 16.7% x

πI

T(AV)

to

πI

T(AV)

1.0
4.5

V

mΩ

Minimum dV/dt

dV/dt

T

j

=125°C, Up to 800V

T

j

=125°C, 1200V – 1800V

500

1000

V/µs

V/µs

Turn-Off Time (Typical)

t

off

T

J

= 125°C

40 - 100 (Typical)

µs

Gate Trigger Current

I

GT

T

j

= 25°C, V

D

=6V, Resistive Load

150

mA

Gate Trigger Voltage

V

GT

T

j

= 25°C, V

D

=6V, Resistive Load

3.0

Volts

Non-Triggering Gate Voltage

V

GDM

T

j

=125°C, V

D

=V

DRM

0.25

Volts

Non-Triggering Gate Current

I

GDM

T

j

=125°C, V

D

=V

DRM

6

mA

Holding Current

I

H

T

j

= 25°C

150

mA

Latching Current

I

L

T

j

= 25°C

300

mA





Thermal Characteristics

Characteristics Symbol

Max.

Units

Thermal Resistance, Junction to Case
DC Operation

R

ΘJ-C

Per Module, both conducting

Per Junction, both conducting


0.33
0.65

°C/W
°C/W

Thermal Resistance, Case to Sink Lubricated

R

ΘC-S

Per Module

0.1

°C/W




























Advertising