Vishay high power products – C&H Technology 87CNQ020APbF User Manual

Page 5

Advertising
background image

www.vishay.com

For technical questions, contact: [email protected]

Document Number: 94261

4

Revision: 13-Aug-08

87CNQ020APbF

Vishay High Power Products

Schottky Rectifier

New Generation 3

D-61 Package, 2 x 40 A

Fig. 5 - Maximum Allowable Case Temperature vs.

Average Forward Current (Per Leg)

Fig. 6 - Forward Power Loss Characteristics (Per Leg)

Fig. 7 - Maximum Non-Repetitive Surge Current (Per Leg)

Fig. 8 - Unclamped Inductive Test Circuit

Note

(1)

Formula used: T

C

= T

J

- (Pd + Pd

REV

) x R

thJC

;

Pd = Forward power loss = I

F(AV)

x V

FM

at (I

F(AV)

/D) (see fig. 6);

Pd

REV

= Inverse power loss = V

R1

x I

R

(1 - D); I

R

at V

R1

= 80 % rated V

R

120

125

130

135

140

145

150

Allowable Case Temperature (°C)

I

F(AV)

- Average Forward Current (A)

30

20

10

40

50

60

0

DC

See note (1)

Square wave (D = 0.50)

80 % rated V

R

applied

0

15

20

10

5

25

Average Power Loss (W)

I

F(AV)

- Average Forward Current (A)

20

10

30

40

60

50

0

DC

RMS limit

D = 0.20
D = 0.25
D = 0.33
D = 0.50
D = 0.75

100

10 000

1000

I

FSM

- Non-Repetitive Surge Current (A)

t

p

- Square Wave Pulse Duration (µs)

100

1000

10 000

10

At any rated load condition
and with rated V

RRM

applied

following surge

Current
monitor

High-speed

switch

D.U.T.

R

g

= 25

Ω

+

Freewheel

diode

V

d

= 25 V

L

IRFP460

40HFL40S02