SD-20

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

CM420890
SCR/Diode POW-R-BLOK™ Modules
90 Amperes/800 Volts

MAXIMUM ON-STATE POWER DISSIPATION

(REVERSE PARALLEL CONNECTION)

RMS ON-STATE CURRENT, I

(RMS)

, (AMPERES)

MAXIMUM POWER DISSIPATION, P

AV(MAX)

, (WATTS)

0

40

80

120

200

160

360

o

RESISTIVE,

INDUCTIVE LOAD

NOTE: THE CURVES INDICATE THE RELATIONSHIP BETWEEN

THE AVERAGE ON-STATE POWER DISSIPATION PER MODULE

AND THE RMS ON-STATE CURRENT.

0

40

80

120

200

160

180

o

120

o

90

o

60

o

= 30

o

MAXIMUM ALLOWABLE CASE TEMPERATURE

(SINGLE PHASE BRIDGE CONNECTION)

DC OUTPUT CURRENT, I

C

, (AMPERES)

MAXIMUM ALLOWABLE CASE TEMPERATURE, T

C

, (

o

C)

0

40

200

80

120

160

80

90

100

110

120

130

= 30

o

60

o

90

o

RESISTIVE,

INDUCTIVE

LOAD

360

o

180

o

NOTE: THE CURVES INDICATE THE RELATIONSHIP BETWEEN

THE CASE TEMPERATURE AND THE DC OUTPUT CURRENT

(FOR TWO ELEMENTS) WHEN USED IN THE SINGLE PHASE

BRIDGE CONFIGURATION.

120

o

MAXIMUM ON-STATE POWER DISSIPATION

(SINGLE PHASE BRIDGE CONNECTION)

DC OUTPUT CURRENT, I

O

, (AMPERES)

MAXIMUM POWER DISSIPATION, P

AV(MAX)

, (WATTS)

0

0

360

o

RESISTIVE,

INDUCTIVE LOAD

NOTE: THE CURVES INDICATE THE RELATIONSHIP BETWEEN

THE AVERAGE ON-STATE POWER DISSIPATION AND THE DC

OUTPUT CURRENT FOR THE SINGLE PHASE BRIDGE

CONFIGURATION (POWER DISSIPATION EXPRESSED FOR EACH

MODULE AND DC OUTPUT CURRENT EXPRESSED FOR THE PAIR)

40

80

120

160

200

240

280

320

40

80

120

160

200

= 30

o

120

o

90

o

60

o

180

o

80

70

60

50

MAXIMUM ALLOWABLE CASE TEMPERATURE

(THREE PHASE BRIDGE CONNECTION)

DC OUTPUT CURRENT, I

O

, (AMPERES)

MAXIMUM ALLOWABLE CASE TEMPERATURE, T

C

, (

o

C)

0

40

200

80 120 160

240 280 320

110

120

130

360

o

NOTE: THE CURVES INDICATE THE RELATIONSHIP BETWEEN

THE CASE TEMPERATURE AND THE DC OUTPUT CURRENT

(FOR THREE MODULES) IN THE THREE PHASE CONFIGURATION.

RESISTIVE,

INDUCTIVE LOAD

= 30

o

60

o

90

o

120

o

100

90

MAXIMUM ON-STATE POWER DISSIPATION

(THREE PHASE BRIDGE CONNECTION)

DC OUTPUT CURRENT, I

O

, (AMPERES)

MAXIMUM POWER DISSIPATION, P

AV(MAX)

, (WATTS)

0

40

200

80 120 160

240 280 320

NOTE: THE CURVES INDICATE THE RELATIONSHIP BETWEEN

THE ON-STATE POWER DISSIPATION (PER MODULE) AND THE

DC OUTPUT CURRENT (FOR THREE MODULES) IN THE THREE

PHASE BRIDGE CONFIGURATION.

360

o

RESISTIVE, INDUCTIVE LOAD

PER SINGLE ELEMENT

= 30

o

120

o

90

o

60

o

0

40

80

120

200

160

Advertising