80PF(R)...(W) Series
Standard Recovery Diodes,
Generation 2 DO-5 (Stud Version), 80 A
Vishay High Power Products
Note
• The table above shows the increment of thermal resistance R
thJC
when devices operate at different conduction angles than DC
Fig. 1 - Current Ratings Characteristics
Fig. 2 - Current Ratings Characteristics
Fig. 3 - Forward Power Loss Characteristics
ΔR
thJC
CONDUCTION
CONDUCTION ANGLE
SINUSOIDAL CONDUCTION
RECTANGULAR CONDUCTION
TEST CONDITIONS
UNITS
180°
0.14
0.10
T
J
= T
J
maximum
K/W
120°
0.16
0.17
90°
0.21
0.22
60°
0.30
0.31
30°
0.50
0.50
Average Forward Current (A)
Maximum Allowable Case Temperature (°C)
110
120
130
140
150
160
170
180
0
10 20 30 40 50 60 70 80 90
30°
60°
90°
120°
180°
Conduction Angle
80PF(R) Series
RthJC = 0.3 K/W
Average Forward Current (A)
Maximum Allowable Case Temperature (°C)
120
130
140
150
160
170
180
0
20
40
60
80
100 120 140
DC
30°
60°
90°
120°
180°
Conduction Period
80PF(R) Series
RthJC (DC) = 0.3 K/W
Average Forward Current (A)
Maximum Allowable Forward Power Loss (W)
Maximum Allowable Ambient Temperature (°C)
0
30
60
90
120
150
180
2 K/W
1.5 K/W
1 K/W
5 K/W
3 K/W
0.3 K/W
0.5 K/W
0.7 K/W
0
20
40
60
80
100
120
140
0
10
20
30
40
50
60
70
80
Conduction Angle
180°
120°
90°
60°
30°
RMS Limit
80PF(R) Series
Tj = 180°C