Datasheet, 10ets..fppbf high voltage series, Vishay high power products – C&H Technology 10ETS..FPPbF High Voltage Series User Manual

Page 2: Rohs

Advertising
background image

Document Number: 94335

For technical questions, contact: [email protected]

www.vishay.com

Revision: 23-Apr-08

1

Input Rectifier Diode

TO-220 FULL-PAK, 10 A

10ETS..FPPbF High Voltage Series

Vishay High Power Products

DESCRIPTION

The 10ETS12FPPbF rectifier series has been
optimized for very low forward voltage drop, with
moderate leakage. The glass passivation
technology used has reliable operation up to
150 °C junction temperature.

Typical applications are in input rectification and these
products are designed to be used with Vishay HPP switches
and output rectifiers which are available in identical package
outlines.
Fully isolated package (V

INS

= 2500 V

RMS

) is UL E78996

approved

This product has been designed and qualified for industrial
level and lead (Pb)-free (“PbF” suffix).

PRODUCT SUMMARY

V

F

at 10 A

< 1.1 V

I

FSM

200 A

V

RRM

800/1200 V

Anode

1

3

Cathode

TO-220AC FULL-PAK

Base

cathode

Available

RoHS*

COMPLIANT

OUTPUT CURRENT IN TYPICAL APPLICATIONS

APPLICATIONS

SINGLE-PHASE BRIDGE

THREE-PHASE BRIDGE

UNITS

Capacitive input filter T

A

= 55 °C, T

J

= 125 °C

common heatsink of 1 °C/W

12.0

16.0

A

MAJOR RATINGS AND CHARACTERISTICS

SYMBOL

CHARACTERISTICS

VALUES

UNITS

I

F(AV)

Sinusoidal waveform

10

A

V

RRM

Range

800/1200

V

I

FSM

200

A

V

F

10 A, T

J

= 25 °C

1.1

V

T

J

- 40 to 150

°C

VOLTAGE RATINGS

PART NUMBER

V

RRM

, MAXIMUM

PEAK REVERSE VOLTAGE

V

V

RSM

, MAXIMUM NON-REPETITIVE

PEAK REVERSE VOLTAGE

V

I

RRM

AT 150 °C

mA

10ETS08FPPbF

800

900

0.5

10ETS12FPPbF

1200

1300

ABSOLUTE MAXIMUM RATINGS

PARAMETER SYMBOL

TEST

CONDITIONS

VALUES

UNITS

Maximum average forward current

I

F(AV)

T

C

= 105 °C, 180° conduction half sine wave

10

A

Maximum peak one cycle
non-repetitive surge current

I

FSM

10 ms sine pulse, rated V

RRM

applied

170

10 ms sine pulse, no voltage reapplied

200

Maximum I

2

t for fusing

I

2

t

10 ms sine pulse, rated V

RRM

applied

130

A

2

s

10 ms sine pulse, no voltage reapplied

145

Maximum I

2

√t for fusing

I

2

√t

t = 0.1 to 10 ms, no voltage reapplied

1450

A

2

√s

* Pb containing terminations are not RoHS compliant, exemptions may apply

Advertising