C&H Technology CC24_ _50 User Manual
Page 4
D-31
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
CN24_ _50, CD24_ _50, CC24_ _50
Fast Recovery Dual Diode Modules
50 Amperes/600-1200 Volts
Electrical and Thermal Characteristics,
Tj = 25°C unless otherwise specified
CN24_ _50
CD24_ _50
Characteristics
Symbol
Test Conditions
CC24_ _50
Units
Blocking State Maximums
Reverse Leakage Current, Peak
IRRM
Tj = 150°C, VRRM = Rated
10
mA
Conducting State Maximums
Peak On-State Voltage
VFM
IFM = 50A
1.5
Volts
Switching Maximums
Reverse Recovery Time
trr
IFM = 50A, Tj = 150°C
0.8
s
di/dt =-100A/
s, VR = 1/2VRM
Reverse Recovery Charge
Qrr
IFM = 50A, Tj = 150°C
30
C
di/dt =-100A/
s, VR = 1/2VRM
Thermal Maximums
Thermal Resistance, Junction-to-Case
R
(J-C)
Per Module
0.6
°C/Watt
Thermal Resistance, Case-to-Sink (Lubricated)
R
(C-S)
Per Module
0.4
°C/Watt