S-35

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

CM530813
Dual SCR POW-R-BLOK™ Modules
130 Amperes/800 Volts

INSTANTANEOUS ON-STATE CURRENT, I

TM

,

(AMPERES)

MAXIMUM

ON-STATE CHARACTERISTICS

10

1

2.4

10

2

10

3

10

4

INSTANTANEOUS ON-STATE VOLTAGE, V

TM

, (VOLTS)

2.0

1.6

1.2

0.8

0.4

T

j

= 125

o

C

CYCLES AT 60 H

Z

MAXIMUM PEAK SURGE (NON-REPETITIVE)

CURRENT, I

TSM

, (AMPERES)

MAXIMUM ALLOWABLE PEAK SURGE

(NON-REPETITIVE) CURRENT

10

1

10

2

10

0

3200

2800

2400

2000

1600

1200

800

400

0

MAXIMUM ALLOWABLE CASE TEMPERATURE

(SINUSOIDAL WAVEFORM)

AVERAGE ON-STATE CURRENT, I

T(AV)

,

(AMPERES)

MAXIMUM ALLOWABLE CASE TEMPERATURE, T

C

, (

o

C)

0

130

360

o

RESISTIVE,

INDUCTIVE

LOAD PER

SINGLE

ELEMENT

120

110

100

90

80

70

60

50

20

40

60

80 100 120 140 160

= 30

o

120

o

60

o

90

o

180

o

MAXIMUM ON-STATE POWER DISSIPATION

(SINUSOIDAL WAVEFORM)

AVERAGE ON-STATE CURRENT, I

T(AV)

,

(AMPERES)

MAXIMUM POWER DISSIPATION, P

AV(MAX)

, (WATTS)

0

0

160

360

o

RESISTIVE, INDUCTIVE LOAD

PER SINGLE ELEMENT

20

40

60

80

100

120

140

20

40

60

80

100 120 140 160

180

o

= 30

o

120

o

60

o

90

o

50

MAXIMUM ALLOWABLE CASE TEMPERATURE

(RECTANGULAR WAVEFORM)

AVERAGE ON-STATE CURRENT, I

T(AV)

,

(AMPERES)

MAXIMUM ALLOWABLE CASE TEMPERATURE, T

C

, (

o

C)

0

60

70

80

90

100

110

120

130

360

o

RESISTIVE, INDUCTIVE

LOAD PER SINGLE

ELEMENT

120

o

270

o

= 30

o

90

o

60

o

DC

40

80

120

160

200

180

o

0

MAXIMUM AVERAGE ON-STATE POWER

DISSIPATION (RECTANGULAR WAVEFORM)

AVERAGE ON-STATE CURRENT, I

T(AV)

,

(AMPERES)

MAXIMUM POWER DISSIPATION, P

AV(MAX)

, (WATTS)

0

360

o

RESISTIVE, INDUCTIVE LOAD

PER SINGLE ELEMENT

40

80

120

160

200

40

80

120

160

200

120

o

180

o

270

o

= 30

o

60

o

90

o

DC

TIME, t, (SECONDS)

TRANSIENT THERMAL IMPEDANCE

CHARACTERISTICS (JUNCTION-TO-CASE)

0

10

-3

0.250

10

-2

10

-1

10

0

TRANSIENT THERMAL IMPEDANCE, Z

(J-C)

(t), (

o

C/WATT)

10

0

10

1

0.225

0.200

0.175

0.150

0.125

0.100

0.075

0.050

0.025

INSTANTANEOUS GATE CURRENT, I

G

, (mA)

TRIGGERING

CHARACTERISTICS

10

1

10

2

10

3

10

4

INSTANTANEOUS GATE VOLTAGE, V

G

, (VOLTS)

10

-1

10

0

10

1

10

2

V

GT

= 3.0V

P

G(AV)

=

3.0W

I

GFM

=

4.0A

I

GT

= 100mA

T

j

= 25

o

C

P

GM

= 10W

V

GDM

= 0.25V

V

GFM

= 10V

MAXIMUM ALLOWABLE CASE TEMPERATURE

(REVERSE PARALLEL CONNECTION)

MAXIMUM ALLOWABLE CASE TEMPERATURE, T

C

, (

o

C)

0

40

200

80 120 160

240 280 300

130

50

360

o

RESISTIVE,

INDUCTIVE LOAD

RMS ON-STATE CURRENT, I

(RMS)

, (AMPERES)

NOTE: THE CURVES INDICATE THE

RELATIONSHIP BETWEEN THE CASE

TEMPERATURE AND THE RMS

ON-STATE CURRENT FOR

EACH MODULE.

= 30

o

120

o

180

o

60

o

90

o

120

110

100

90

80

70

60

Advertising