Cd43 c – C&H Technology CD43__90C User Manual

Page 4

Advertising
background image

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272

POW-R-BLOK

TM

http://www.pwrx.com

Dual SCR Isolated Module

90 Amperes / Up to 1800 Volts

Revision Date: 08/31/2011

CD43__90C

®

Electrical Characteristics, T

J

=25°C unless otherwise specified

Characteristics

Symbol

Test Conditions

Min.

Max.

Units

Repetitive Peak Forward Leakage Current

I

DRM

Up to V

DRM

, T

J

=125°C

10

mA

Repetitive Peak Reverse Leakage Current

I

RRM

Up to V

RRM

, T

J

=125°C

10

mA

Peak On-State Voltage

V

TM

I

TM

=270A

1.70

V

Threshold Voltage, Low-level
Slope Resistance, Low-level

V

(TO)1

r

T1

T

J

= 125°C, I = 16.7% x

I

T(AV)

to

I

T(AV)

0.8

3.01

V

m

Ω

Minimum dV/dt

dV/dt

T

j

=125°C, V

DM

= 0.67 V

DRM

800

V/µs

Gate Trigger Current

I

GT

T

j

= 25°C, V

D

=12V, I

A

= 1 A

30

100

mA

Gate Trigger Voltage

V

GT

T

j

= 25°C, V

D

=12V, I

A

= 1 A

1.0

2.5

Volts

Holding Current

I

H

T

j

= 25°C, V

D

=12V, I

A

= 1 A

20

100

mA

Thermal Characteristics

Characteristics

Symbol

Max.

Units

Thermal Resistance, Junction to Case
DC Operation

R

ΘJ-C

Per Junction, both conducting


0.28

°C/W

Thermal Resistance, Case to Sink Lubricated

R

ΘC-S

Per Module

0.15

°C/W

Advertising