Datasheet, Input rectifier diode, 80 a, 80eps..pbf high voltage series – C&H Technology 80EPS..PbF High Voltage Series User Manual

Page 2: Vishay high power products, Rohs

Advertising
background image

Document Number: 94347

For technical questions, contact: [email protected]

www.vishay.com

Revision: 06-Jun-08

1

Input Rectifier Diode, 80 A

80EPS..PbF High Voltage Series

Vishay High Power Products

DESCRIPTION/FEATURES

The 80EPS..PbF rectifier High Voltage Series

has been optimized for very low forward voltage

drop, with moderate leakage. The glass

passivation technology used has reliable

operation up to 150 °C junction temperature.

Typical applications are in input rectification and these

products are designed to be used with Vishay HPP switches

and output rectifiers which are available in identical package

outlines.

This product has been designed and qualified for industrial

level and lead (Pb)-free.

PRODUCT SUMMARY

V

F

at 80 A

1.17 V

I

FSM

1450 A

V

RRM

800/1200 V

TO-247AC

Anode

1

3

Base

cathode

Anode

4, 2

Available

Pb-free

RoHS*

COMPLIANT

MAJOR RATINGS AND CHARACTERISTICS

SYMBOL

CHARACTERISTICS

VALUES

UNITS

I

F(AV)

Sinusoidal waveform

80

A

V

RRM

Range

800/1200

V

I

FSM

1450

A

V

F

80 A, T

J

= 25 °C

1.17

V

T

J

- 40 to 150

°C

VOLTAGE RATINGS

PART NUMBER

V

RRM

, MAXIMUM

PEAK REVERSE VOLTAGE

V

V

RSM

, MAXIMUM NON-REPETITIVE

PEAK REVERSE VOLTAGE

V

I

RRM

AT 150 °C

mA

80EPS08PbF

800

900

1

80EPS12PbF

1200

1300

ABSOLUTE MAXIMUM RATINGS

PARAMETER SYMBOL

TEST

CONDITIONS

VALUES

UNITS

Maximum average forward current

I

F(AV)

T

C

= 100 °C, 180° conduction half sine wave

80

A

Maximum peak one cycle
non-repetitive surge current

I

FSM

10 ms sine pulse, rated V

RRM

applied

1450

10 ms sine pulse, no voltage reapplied

1500

Maximum I

2

t for fusing

I

2

t

10 ms sine pulse, rated V

RRM

applied

10 500

A

2

s

10 ms sine pulse, no voltage reapplied

14 000

Maximum I

2

√t for fusing

I

2

√t

t = 0.1 to 10 ms, no voltage reapplied

105 000

A

2

√s

* Pb containing terminations are not RoHS compliant, exemptions may apply