Milton CAT G3412 375 kW Continuous 375 kW 60 Hz Performance and Sound Data User Manual

G3412c

Advertising
background image

G3412C

GAS ENGINE TECHNICAL DATA

ENGINE SPEED:

1800

FUEL:

COMPRESSION RATIO:

11.4:1

FUEL SYSTEM:

LPG IMPCO

AFTERCOOLER - MAX. INLET (°F):

130

JACKET WATER - MAX. OUTLET (°F):

210

FUEL PRESS. RANGE (PSIG):

1.5 - 5.0

COOLING SYSTEM:

JW+OC, AC

MIN. METHANE NUMBER:

80

IGNITION SYSTEM:

EIS

RATED ALTITUDE (FT):

4922

EXHAUST MANIFOLD:

WC

AT AIR TO TURBO. TEMP. (°F):

77

COMBUSTION:

LOW EMISSION

NOx EMISSION LEVEL:

1.9 g/bhp-hr

FUEL LHV (BTU/SCF):

905

APPLICATION:

60 Hz GENSET

NOTES

LOAD

100%

75%

50%

ENGINE POWER

(WITHOUT FAN)

(1)

BHP

637

478

318

GENERATOR POWER

(WITH MECH FAN)

(2)

EKW

375

259

154

ENGINE EFFICIENCY

(ISO 3046/1)

(3)

%

37.0

35.4

32.8

ENGINE EFFICIENCY

(NOMINAL)

(3)

%

36.3

34.7

32.2

THERMAL EFFICIENCY

(NOMINAL)

(4)

%

42.4

44.6

50.9

TOTAL EFFICIENCY

(NOMINAL)

(5)

%

78.6

79.3

83.1

FUEL CONSUMPTION

(ISO 3046/1)

(6)

BTU/bhp-hr

6887

7192

7753

FUEL CONSUMPTION

(NOMINAL)

(6)

BTU/bhp-hr

7021

7332

7904

AIR FLOW (77 °F, 14.7 psi)

(7)

SCFM

1354

1047

673

AIR FLOW

(7)

lb/hr

6003

4641

2983.00

COMPRESSOR OUT PRESSURE

in. HG (abs)

66.3

63.2

47.4

COMPRESSOR OUT TEMPERATURE

°F

286

265

200

AFTERCOOLER AIR OUT TEMPERATURE

°F

148

145

140

INLET MAN. PRESSURE

(8)

in. HG (abs)

59.5

52.9

47.8

INLET MAN. TEMPERATURE

(MEASURED IN PLENUM)

(9)

°F

148

145

140

TIMING

(10)

°BTDC

27

27

27

EXHAUST STACK TEMPERATURE

(11)

°F

700

700

727

(12)

CFM

3153

2440

1616

EXHAUST MASS FLOW

(12)

lb/hr

6229

4818

3110

NOx (as NO2)

(13)

g/bhp-hr

1.9

2

5.4

CO

(14)

g/bhp-hr

1.93

1.96

2.05

THC (molecular weight of 15.84)

(14)

g/bhp-hr

5.35

5.87

5.05

NMHC (molecular weight of 15.84)

(14)

g/bhp-hr

0.8

0.88

0.76

EXHAUST O2

(15)

% DRY

8.7

8.5

6.9

LAMBDA

(15)

1.68

1.66

1.48

LHV INPUT

(16)

BTU/min

74538

58378

41956

HEAT REJECTION TO JACKET (JW)

(17) (22)

BTU/min

18937

16021

13908

HEAT REJECTION TO ATMOSPHERE

(18)

BTU/min

2982

2335

1678

HEAT REJECTION TO LUBE OIL (OC)

(19) (22)

BTU/min

2994

2533

2199

HEAT REJECTION TO EXHAUST (LHV to 77°F)

(20)

BTU/min

18962

14775

9862

HEAT REJECTION TO EXHAUST (LHV to 350°F)

(20)

BTU/min

9647

7467

5236

HEAT REJECTION TO A/C (AC)

(21) (23)

BTU/min

3626

2436

790

CONDITIONS AND DEFINITIONS

ENGINE RATING IS WITH 2 ENGINE DRIVEN WATER PUMPS.

FOR NOTES INFORMATION CONSULT PAGE THREE.

DM5444-02

03-Mar-09

PAGE 1 OF 3

ENGINE RATING OBTAINED AND PRESENTED IN ACCORDANCE WITH ISO 3046/1STD. REF. CONDITIONS OF 77°F, 29.6 IN
HG BAROMETRIC PRESSURE, 500 FT ALTITUDE). NO OVERLOAD PERMITTED AT RATING SHOWN. CONSULT ALTITUDE
CHARTS FOR APPLICATIONS ABOVE MAXIMUM RATED ALTITUDE AND/OR TEMPERATURE.

EMISSION LEVELS ARE BASED ON THE ENGINE OPERATING AT STEADY STATE CONDITIONS AND ADJUSTED TO THE
SPECIFIED NOx LEVEL AT 100% LOAD. EMISSION TOLERANCES SPECIFIED ARE DEPENDANT UPON FUEL QUALITY.
METHANE NUMBER CANNOT VARY MORE THAN ± 3. PUBLISHED PART LOAD DATA MAY REQUIRE ENGINE ADJUSTMENT.

NAT GAS

HEAT BALANCE DATA

EMISSIONS DATA

ENGINE DATA

RATING AND EFFICIENCY

EXHAUST GAS FLOW (@ stack temp.)