Control System

Electronic management

Monitor Display Screen

The monitor is a full color, 400 × 234 pixels Liquid Crystal
Display (LCD). A master caution lamp blinks ON and OFF
when one of the critical conditions below occurs:

Engine oil pressure low

Coolant temperature high

Hydraulic oil temperature high

Under normal conditions or the default condition, the monitor
display screen is divided into four areas: clock and throttle
dial, gauge, event display and multi-information display.

Gauge Display

Three analog gauges, fuel level, hydraulic oil temperature
and coolant temperature are displayed in this area.

Electronic Joysticks

Electronic joysticks provide features not possible
with hydraulic pilot valves:

Eliminate pilot lines in cab for quieter operation

Simple pattern change through the monitor

Operator Gain/Response

This is used to suit the operator preference or application.

Quicker for fast response

Slower, for more precision

Contains three preset settings with 21 available

Pattern Control Changer

The standard hand control pattern changer can be accessed
through the monitor, to utilize either the standard excavator
control pattern (SAE) or Backhoe Loader pattern (BHL).

Alternator

The alternator is 24 volt with 75 amp capacity and is driven
by a serpentine belt off the front pulley. A snorkel pulls cool,
clean air from the outside for increased service life.

Product Link

Product Link is standard on the 374D L. Product Link
transmits diagnostic information from the machine back
to Caterpillar, Cat dealers and customers.