Cooling or heating mode, Air-conditioner or heater active – Velleman VMB1TSW User Manual

Page 14

Advertising
background image

Cooling or heating mode

When the temperature sensor is configured to control an air-conditioning system, the frost flower LED (upper LED)
will be lit. Setting the heating or cooling mode can only be done through a temperature controller (VMB1TC /
VMB1TCW) or through the Velbus link program.

Heating mode

Cooling mode


Air-conditioner or heater active

When the heater (valve open) or air-conditioner is active, a red LED will be lit.


The red output LED can indicate following error conditions:

Flashing (short on, long off): the heater/cooler should be off but it did not

receive the command from the relays module.

Flashing (short off, long on): the heater/cooler should be on but it did not

receive the command from the relays module.

Fast flashing: configuration of the sensor chip failed.


Note: as long as the error condition exists the output status wil be re-
transmitted every minute.