Velleman VDPL303WQD User Manual

Page 3

Advertising
background image

VDPL303WQD

22.03.2010

©Velleman nv

3

4. Features

• DMX-controlled via 2 channels

• stand-alone, master/slave or sound-activation mode

• adjustable rotation speed via DMX mode

• starts in auto mode when no DMX signal is present

5. Installation

a) Mounting the Device
• Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable

norms.

• The carrying construction must be able to support 10 times the weight of the device for 1 hour without

deforming.

• The installation must always be secured with a secondary attachment e.g. a safety cable.

• Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified

technician check the device once a year and once before you bring it into service.

• Install the device in a location with few passers-by that is inaccessible to unauthorised persons.

• Overhead mounting requires extensive experience: calculating workload limits, determining the

installation material to be used… Have the material and the device itself checked regularly. Do not

attempt to install the device yourself if you lack these qualifications as improper installation may result

in injuries.

• Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws.

• Make sure there is no flammable material within a 0.5 m radius of the device.

• Have a qualified electrician carry out the electric connection.

• Connect the device to the mains with the power plug. Do not connect it to a dimming pack.

• The installation has to be approved by an expert before the device is taken into service.
b) Fuse Replacement
• Only fit or replace a fuse when the device is unplugged from the mains.

• Replace a blown fuse with a fuse of the same type and rating (see “Technical Specifications”):

1. Remove the fuse holder using a flat-head screwdriver.

2. Remove the old fuse and install a new one.

3. Replace the fuse holder.

6. Use

Stand-Alone Operation
In stand-alone operation, the device can be used without a controller. A single unit will react to the

surrounding sounds through the built-in microphone. Set all DIP switches to OFF. Use the adjustment

knob at the back of the unit to adjust the sensitivity.
Master/Slave Operation
The master/slave operation enables several devices to be controlled synchronically by the master unit.

Interconnect all units using XLR cables. Set all DIP switches on the master unit to OFF; set DIP switches

1 and 10 on the slave units to ON. All slave units will follow the master unit’s pattern.

7. DMX Mode

The DMX mode allows you to control the unit through a universal DMX controller. Set DIP switch 10 to

ON to activate the DMX mode, set the DMX address using DIP switches 1 to 9.
Detailed DMX Values per Channel

Channel Function

From

To

Description

1 Control

0 14

No

function

15 100

ON

101 255

Auto

effects

2 Rotation

0 85

S>F

CCW

86 170

S>F

CW

171

255

S>F, left>right

DMX512 Connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to

the male 3-pin XLR input of the VDPL303WQD. Multiple VDPL303WQDs can be linked through serial

linking. The linking cable should be a two-core screened cable with XLR input and output connectors.

Advertising