Use

• When the solar charge regulator is initialized, the display shows:

S O L A R

• At any time, press the OK button to see the battery voltage, the charging current and

the loading current sequentially (interval ±4s):

B a t t e r y x x . x V

C h a r g e x x . x A

L o a d x x . x A

• Press the MENU button repeatedly to scroll through the menus:

1. Show the current system temperature

T e m p e r a t u r e x x C

2. Show the charging current

C h a r g e 0 0 0 0 0 0 A h

3. Show the discharging current

L o a d 0 0 0 0 0 0 A h

4. Show the battery capacity

B a t t e r y S O C x x %

5. Check/set up the charge-off voltage limit (use the

and/or

buttons to

change the value)

C h a r g e o f f 1 3 . 8 V

6. Check/set up the load-off voltage limit (use the

and/or

buttons to change

the value)

L o a d o f f 1 0 . 5 V

7. Check/set up the load-on voltage limit (use the

and/or

buttons to change

the value)

L o a d o n 1 2 . 5 V

• To reset the SOL30UC2 to default values, press and hold the MENU button for ±5s.

8.

Troubleshooting

Problem: load indicator [2] off, display shows “Battery low” and load stops working.

Reason: low battery voltage.

Possible solutions:

• Remove load and press the RESET button. When battery is fully charged, reconnect

the load.

• Increase the number of solar panels or change the battery to match the connected

load.

Problem: load indicator [2] off, display shows “overload” and load stops working.
Reason: system overloaded.

Possible solutions: remove as much load as necessary and press the RESET button.
Problem: load indicator [2] off, display shows “short circuit” and load stops working.
Reason: short circuit inside the load.

Possible solutions:

• Resolve the short circuit problem on the load and press the RESET button.