4. Overview

Refer to the drawing on page 3 of this manual.

1. Over-discharge indicator
2. Digital voltage meter
3. Digital voltage meter on/off switch
4. USB output

5. Inverter female CLA (Cigarette Lighter Adapter) output
6. On/Off switch
7. 12VDC female CLA output
8. Female output connectors for 3VDC, 6VDC and 12VDC (2x)
9. Connectors for battery

10. Fuse
11. Connectors for solar panel

5. Installation

 Place the regulator in a dry location. Make sure the switch [6] is in the off-

position.

 First connect a 12V rechargeable battery (not included) to connector [9]. Use

the correct polarity!

 Then connect a device or appliance (not included) to connector [4], [7] or

[8], or an AC converter to connector [5]. Make sure the connected load is in
accordance with the specifications of this regulator and switched off.

Note: the power from connector [5] comes straight from the battery and is not

regulated by the regulator.

 Finally connect a solar panel (not included) to connector [11]. Make sure the

connected solar panel is in accordance with the specifications of this regulator.
Use the correct polarity!

 Verify whether all connections are tight and secure.

Do not short circuit or reverse polarity of battery, solar panel or
load, as this will lead to irreversible damage.

 To disconnect the regulator, first switch it off, and then disconnect the solar

panel, the load and finally the battery.

 Note that short connection wires will reduce power losses.

6. Use

 Switch on the regulator with switch [6].

 The digital voltage meter [2] shows the current battery voltage. It can be

switched off to save electricity. To switch it on or off, push the digital voltage
meter on/off switch [3].

 When LED [1] lights up, the regulator is in over-discharge protection mode.

This will be the case when the battery voltage drops below 11±0.5VDC. The
power to the output connectors [5, 7, 8] is cut off to prevent damage to the

battery. Remove the load from the connector and wait until the battery is fully
recharged.

 When the battery voltage is above 14.5±0.5VDC, the regulator goes in over-

charge protection mode. The power from the solar panel input connector

Advertising