Other functions, Display description – Velleman VTBAL6 User Manual

Page 4

Advertising
background image

VTBAL6_v3

VELLEMAN

4

5. Other Functions

5.1. Setting the Auto Power-Off Timer

Switch on the scales.

Hold both and keys pressed to enter the setting mode.

Set the timer using the numeric keys (timer range from 0 ~ 30 min). The scales will not switch off automatically when the timer is set
to 0.

Press to confirm your choice.


Note: This function is only valid when powering the scales with a battery.

5.2. Calibration

Switch on the scales.

Hold both and keys pressed to enter the calibration mode.

Calibrate the zero point first. The scales display unit.0 in the PIECE WEIGHT window. Make sure there is no object on the platform.
Press .

The scales display unload in the PIECE WEIGHT window. Press to calibrate the zero point.

The scales will now display load in the PIECE WEIGHT window. Place a reference weight onto the platform. The reference weight
must be 25% ~ 100% FS. Press when the displayed value has stabilised.

The scales display inp.ld in the PIECE WEIGHT window. Now, enter the reference weight’s value using the numeric keys and press

to confirm.

Remove the reference weight from the platform and press to confirm the zero point again.

The scales will now automatically reset and return to the normal weighing mode. Exit the calibration mode by pressing . A
calibration error will be reported by cal.err.

6. Display Description


- - - - - -

Overload or overrange

- - - - - -

Uncertain value

- - - - - -

Weight signal is too small

0- - - - -

Zero point is too high

0- - - - -

Zero point is too low

Eep.er0

EEPROM cannot be accessed

Eep.er1

The EEPROM parameters differ from the backup data

Eep.er2

The parameter has not been set

Cal.err

Calibration error

Ad- - - -

Input signal over maximum range

Ad- - - -

Input signal under minimum range

Cap

Capacity-related data display

Uol

Voltage-related data display

Add

Totalised data

Pc.t

Piece weighing

Spl.pcs

Sample quantity

Up.pcs

Upper limit

Lo.pcs

Lower limit

Unload

Unload the weight from the platform

Inp.ld

Load the weight onto the platform

Cal.on

Calibration mode enabled

Cal.off

Calibration mode disabled


Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury
resulted from (incorrect) use of this device.

For more info concerning this product, please visit our website www.velleman.eu.
The information in this manual is subject to change without prior notice.

Advertising