b. DMX-512 connection

When applicable, connect an XLR cable to the female 3-pin XLR output of a controller (not incl.) and the
other side to the male 3-pin XLR input [9] of the VDPL3603MHW11. Multiple VDPL3603MHW11’s can be

linked through serial linking. The linking cable should be a dual core, screened cable with XLR input and

output connectors.

Maximum recommended serial data link distance is 500 meters (1640 ft). Maximum recommended number

of fixtures on a serial data link is 32 fixtures.

A DMX terminator is recommended for installations where the DMX cable has to run a long distance or is in
an electrically noisy environment (e.g. discos). The terminator prevents corruption of the digital control

signal by electrical noise. The DMX terminator is simply an XLR plug with a 120Ω resistor between pins 2

and 3, which is then plugged into the XLR output socket [10] of the last device in the chain.

c. General

Make sure there is no flammable material within a 50cm radius of the device and there is sufficient cooling.

Have a qualified electrician carry out the electrical connection.

Connect the device to the mains with the power plug. All fixtures must be powered directly off a grounded

switched circuit and cannot be run off a rheostat or dimmer circuit, even if the rheostat or dimmer channel
is used solely for 0% to 100% switch.

The installation has to be approved by an expert before the device is taken into service.

d. Replacing the fuse [8]

Only replace the fuse by a fuse of the same type and rating.
1. Before replacing the fuse, unplug the mains lead.
2. Unscrew the fuse holder on the rear panel of the base with an appropriate screwdriver.
3. Remove the old fuse and install the new fuse in the fuse holder.
4. Replace the fuse holder in the housing and tighten it.

6. Operation

Refer to the illustrations on page 2 of this manual.

a. Control Panel Navigation

Access the control panel functions using the four panel buttons [4] located directly underneath the

display [5]. From left to right:

button function
<MODE>

used to access the menu or to return to a previous menu option

<ENTER>

used to select and store the current menu or option within the menu

<UP>

scrolls through the menu options in ascending order

<DOWN>

scrolls through the menu options in descending order

The control panel display shows the menu items you select from the menu map. To select a menu item,

press <ENTER>.

Use the <UP> and <DOWN> buttons to navigate the menu map and menu options. Press <ENTER> to

access the menu function currently displayed or to enable a menu option. To return to the previous option

or menu without changing the value, press the <MODE> button.

b. Menu Functions

function display

description

DMX-mode <Addr> <A001>

<A512>

Set DMX starting address between 1 and 512.

pan <PAn>

<No>

pan

normal

<Yes>

pan

inverse

tilt <tilt>

<No>

tilt

normal

<Yes>

tilt

inverse