Features, Overview, Installation – Velleman VDPSPxN User Manual

Page 5: Operation

Advertising
background image

VDPSPxN

20.04.2011

©Velleman nv

5

temperature.

Keep this manual for future reference.

4. Features

wall or rack mounting (1U)

1 input to 4 outputs (VDPSP4N) / 1 input to 8 outputs (VDPSP8N)

DMX Thru

electronic isolation between in-and output

terminator button for last unit

power and signal indicator

5. Overview

Refer to the illustrations on page 2 of this manual.

1 DMX in – 3 & 5 pins

5 mounting bracket (2x)

2 LED indicators per channel

6 power connector + fuse

3 terminator button

7 DMX out*

4 ON/OFF power switch

8 DMX thru – 3 & 5 pins

* VDPSP4N: 4x 3 pins + 4x 5 pins / VDPSP8N: 8x 3 pins

6. Installation

a) mounting

The mounting brackets [5] can be mounted in 3 positions on the side of the device: front,

bottom or back. Place the brackets in front or back position for 19” rack mounting, or in bottom

position for wall mounting.

Unscrew both screws that hold each bracket and place the bracket in the desired position.

Retighten the screws.

Make sure to install the VDPSPxN in a dry location with a normal airflow for sufficient cooling.

b) DMX-512 connections

Make sure all devices are switched off and disconnected from the mains before making any

connections.

Connect an XLR cable to the female 3-pin XLR output of a controller (not incl.) and the other

side to the male 3- or 5-pin XLR input [1] of the VDPSPxN.

To link multiple VDPSPxNs obtain a suitable linking cable (not incl.). Connect the cable to the

female (=out) DMX Tru connector [8] of the VDPSPxN and the other end to the male (=in)

DMX in connector [1].

Notes:

Do not use both 3-pin and 5-pin input or output simultaneously.

The linking cable should be a dual core, screened cable with XLR input and output

connectors.

Maximum recommended serial data link distance is 500 meters (1640 ft). Maximum

recommended number of fixtures on a serial data link is 32 fixtures.

On the last VDPSPxN in the chain, enable the DMX terminator by pressing the terminator

button [3]. The terminator prevents corruption of the digital control signal by electrical noise.

Connect your DMX devices (not incl.) to the female output ports [7] at the back of the

VDPSPxN.

VDPSP4N: only use either the 3-pin or 5-pin output connector of an output channel; never

connect DMX devices to both output ports at the same time.

Note: every last device on a DMX chain connected to an output [7] of the VDPSPxN must get

its own terminator. The DMX terminator is simply an XLR plug with a 120Ω resistor between

pins 2 and 3, which is then plugged into the XLR output socket of the last device in the chain.

7. Operation

Have a qualified electrician carry out the electrical connection.

Connect the device to the mains with the power plug. All fixtures must be powered directly off a

grounded switched circuit and cannot be run off a rheostat or dimmer circuit, even if the rheostat

or dimmer channel is used solely for 0% to 100% switch.

When all connections are made and verified, switch on the VDPSPxN with the ON/OFF switch

[4].

The red LEDs [2] switch on when the DMX output channels are powered; the green LEDs [2]

indicate the presence of a DMX signal on the indicated channel.

Advertising