Wiring, Technical specifications – Velleman SOL15 User Manual

Page 4

Advertising
background image

SOL15/SOL16_v5

VELLEMAN

4

4. Wiring


Earthing




The ground wire should be connected to the module frame or, better, to one of the
M6 fixing screws (see fig.).


5. Technical Specifications

SOL15

SOL16

max. power

15W ± 5%

40W

open circuit voltage (V

oc

)

21 ~ 23V

61V

max. working voltage (V

mp

) 17.5V

46V

max. working current (I

mp

) 850mA 870mA

cable length

± 1.8m

±1m

operation temperature

-40°C ~ 85°C

-40°C ~ 85°C

storage temperature

-40°C ~ 85°C

-40°C ~ 85°C

dimensions

923 x 313 x 22mm

643 x 1253 x 37mm

weight 4.9kg

14.7kg

extension cable (not incl.)

SOL/SPC1

SOL/SPC2

optional voltage controllers (not incl.)

SOL4UCN2

SOL7UC

SOL30UC12V

(*)

SOL30UC24V

* use a SOL30UC24V when installing two SOL15s in series


Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or
injury resulted from (incorrect) use of this device.

For more info concerning this product, please visit our website www.velleman.eu.
The information in this manual is subject to change without prior notice.

© COPYRIGHT NOTICE
This manual is copyrighted. The copyright to this manual is owned by Velleman Components nv. All worldwide rights reserved. No part of this manual may be
copied, reproduced, translated or reduced to any electronic medium or otherwise without the prior written consent of the copyright holder.

Advertising