Troubleshooting, Technical specifications – Velleman WS1170 User Manual

Page 6

Advertising
background image

WS1170

Rev. 04

07.03.2011

©Velleman nv

6

• The alarm will automatically reactivate once the value has

fallen below the set temperature value or if a new value is
entered.

The outdoor weather alarm

When a set outdoor alarm has been triggered, it will flash on the
LCD display. The general outdoor alarm icon and HI / LO alarm

icon will flash accordingly. Example: In outdoor temperature

mode, the dew point icon will flash along the outdoor alarm and
the HI alarm icons when the dew point HI alarm is triggered.

This will indicate that the current alarm source is from the dew

point.

d. MIN / MAX Mode

• Press MIN / MAX to enter the MAX mode. MAX and the

maximum record will be displayed.

• Press MIN / MAX to enter the MIN mode. MIN and the minimum

record will be displayed.

• Press MIN / MAX to return to the normal display mode.

• In MAX mode, press + to display the following maximum values with their time and date: Indoor

humidity maximum – Indoor temperature maximum – Outdoor humidity maximum – Outdoor

temperature maximum – Pressure maximum.

• In MIN mode, press + to display the following minimum values with their time and date: Indoor humidity

minimum – Indoor temperature minimum – Outdoor humidity minimum – Outdoor temperature minimum
– Pressure minimum.

• In MIN or MAX mode, hold SET pressed for 2 seconds to reset the respective value, time and date.

• Press SNOOZE / LIGHT to return to the normal display mode

9. Troubleshooting

Problem Possible

Cause

Solution

Transmission problem • Distance between the two units is too long

• Shielding materials between two units

(thick wall, steel…)

• Interference from other sources

• Reduce distance
• Find a different mounting location
• Eliminate interference sources

Data on LCD is illegible • No data reception

• Low batteries

• Find a different mounting location
• Replace batteries

Incorrect data

• Low batteries
• Incorrect settings

• Replace batteries
• Reprogram the weather station

10. Technical specifications

Indoor Station

Temperature Range

0°C ~ +60°C (OFL displayed when out of range)

Resolution 0.1°C

Relative Humidity

1% ~ 99%

Resolution 1%

Atmospheric Pressure

919 hPa ~ 1080 hPa

Resolution / Accuracy 0.1 hPa / 1.5 hPa

Alarm Duration

120 sec

Outdoor Station

Transmission Range in Open Field max. 100m
Frequency 433MHz
Temperature Range

-40°C ~ +65°C (OFL displayed when out of range)

Resolution 0.1°C

Relative Humidity

20% ~ 95%

Humidity Accuracy +/- 5% under 0°C ~ 45°C

Power Supply

Indoor Station

3 x 1.5V AA alkaline batteries (not incl.) for battery life

of 6 months

Outdoor Station

2 x 1.5V AAA alkaline batteries (not incl.) for battery

life of 12 months

Use this device with original accessories only. Velleman nv cannot be held responsible in the event

of damage or injury resulted from (incorrect) use of this device.
The information in this manual is subject to change without prior notice.