Velleman PIR1200R User Manual

Page 2

Advertising
background image

PIR1200R VELLEMAN

2







5. Wiring Diagram

1. brown

2. blue
3. red
4. input
5. output

6. lamp
7. sensor

6. Test

Turn the adjustment anticlockwise until the max. position is reached and turn the adjustment anticlockwise
until the min. position is reached.

It takes the device some 5 to 10 sec. to react when movement is detected. The lamp will light for 5 to 15 sec.


7. Notes

A qualified electrician should install this device.

Do not block the front of the detection window and make sure the detection area holds no moving objects.

Do not install the device close to air conditioning vents, radiators, etc.

Do not open the housing and attempt to repair the device yourself in case of malfunction. Only skilled technicians

should repair this device.


8. Troubleshooting

Problem Solution

The lamp doesn’t work

Check the power supply and the lamp.
An object may be blocking the detection window.
Check the ambient temperature.
Please check if the signal source is located within the
boundaries of the detection range.
Check the installation height.

Sensitivity is poor

Check if the moving orientation is right.
Movement is continually detected.
The activation duration is too long.

The lamp doesn’t extinguish.

Dramatic temperature changes in close vicinity to the

sensor. These may be caused by e.g. air conditioning
vents or central heating elements, etc.

The contents of this manual are subject to modifications without prior notice.

Fig. 3

Fig. 4

Advertising