Velleman VPASG100 User Manual

Page 5

Advertising
background image

VPASGx00

11.05.2010

©Velleman nv

5

6. Troubleshooting

The amplifier stops working.

Turn the volume knobs of both channels to zero, switch off the amplifier and disconnect from the

mains. Check the front panel, the fuse and all input and output connections. Replace the fuse with a

fuse of the same type and ratings.

No sound when power LED is switched off.

The power supply is not connected or the amplifier has a blown fuse. Check the power connections

and switches, or replace the fuse located below the power input.

No sound when power LED is switched on.

No or low input, or faulty speakers. Check if the input is connected and if the LED shows the

presence of a signal. Gently increase the volume level and check the speakers and speaker

connections.

Hum or buzz.

Power supply noise is picked up in the signal path or earth problem. Only use good quality, shielded

signal cables and ensure they are kept away from the power cables and other AC-powered

equipment. Use a mains tester to ensure the mains outlet has a good earth.

Distorted sound.

There is an excessive signal level or damaged signal cables. Check the LED to ensure the input level

to the amp is at the correct level. Only use good quality, shielded signal cables and protect them

from damage.

Sound cuts out.

The signal cables are damaged or the connectors are not properly inserted. Check all cables and

connections.

Protect LED on

• Check if the amplifier is not overheated. Clean ventilation openings when necessary.

• Check whether the connected speakers have the appropriate impedance. If not, connect speakers

with sufficient impedance. Also verify that the speakers are not short-circuited. Inspect the wiring.

• Inputs receive DC voltage or another technical fault condition has occurred. Switch off the amplifier

and contact your local dealer for servicing.

7. Maintenance

• Regularly wipe the amplifier with a moist, lint-free cloth. Do not use alcohol or solvents.

• Ensure that liquids are not spilled into the enclosure through the ventilation openings.

• Contact your HQPower™ dealer if your amplifier needs servicing.

8. Technical Specifications

VPASG100 VPASG200 VPASG300

RMS power

4Ω

120Wrms 250Wrms 400Wrms

8Ω 80Wrms

180Wrms

280Wrms

S/N ratio

> 85dB

> 90dB

> 90dB

weight 9.5kg

10.5kg

12

kg

Use this device with original accessories only. Velleman nv cannot be held responsible in the

event of damage or injury resulted from (incorrect) use of this device. For more info

concerning this product and the latest version of this manual, please visit our website

www.hqpower.eu. The information in this manual is subject to change without prior notice.


© COPYRIGHT NOTICE

The copyright to this manual is owned by Velleman nv. All worldwide rights reserved.

No part of this manual or may be copied, reproduced, translated or reduced to any electronic medium or

otherwise without the prior written consent of the copyright holder.