Troubleshooting – Velleman DVM171THD User Manual

Page 4

Advertising
background image

DVM171THD

V. 03 – 12/06/2013

4

©Velleman nv

6. If the data logger is set up to start manually (delayed start), the green LED

[6] will flash two times every 10 seconds. Press the Start button [3] until the
green [6] and yellow LED [5] flash once (together). The data logger starts

logging and the green LED [6] will flash every 10 seconds (increase this value
through the setup procedure to increase battery life).

7. To download the data into the personal computer, start the data logger

software, remove the protective cover [1] and plug the data logger into a free

USB slot.

Refer to the help function of the data logger software (Help > Help topics…) for
more information on downloading and handling the data from the data logger.

6. Troubleshooting

Both LEDs are off

Logging is not active or battery is low. Start logging or replace battery.

1x

Green REC LED [6], flashes 1 x every 10 seconds
Logging, no alarm condition.

2x

Green REC LED [6], flashes 2 x every 10 seconds

Delayed start mode.

1x

Red ALM LED [5], flashes 1 x every 10 seconds
Logging, humidity lower limit exceeded.

2x

Red ALM LED [5], flashes 2 x every 10 seconds

Logging, humidity upper limit exceeded.

1x

Red ALM LED [5], flashes 1 x every 60 seconds
Low battery. Logging will stop, replace battery and download data.

1x

Yellow ALM LED [5], flashes 1 x every 10 seconds

Logging, temperature lower limit exceeded.

2x

Yellow ALM LED [5], flashes 2 x every 10 seconds
Logging, temperature higher limit exceeded.

1x

Yellow ALM LED [5], flashes 1 x every 60 seconds
Logger memory full. Logging will stop, download data.