AVM52ERT VELLEMAN

1

AVM52ERT – Analogue Earth Resistance Tester

1. Introduction & Features

To all residents of the European Union
Important environmental information about this product

This symbol on the device or the package indicates that disposal of the device after its
lifecycle could harm the environment. Do not dispose of the unit (or batteries) as
unsorted municipal waste; it should be taken to a specialized company for recycling.
This device should be returned to your distributor or to a local recycling service. Respect

the local environmental rules.
If in doubt, contact your local waste disposal authorities.

Thank you for buying the AVM52ERT ! Please read the manual carefully before bringing this
device into service.

• The modern design limits the influence of the earth voltage and the earth resistance of

auxiliary earth bars to a minimum.

• Press the BATT.CHECK button to test the auxiliary earth resistance and the connection

cable. The OK lamp lights up when the device is ready to perform accurate earth resistance
measurements.

• Low power consumption : max. 12V/100mA.

• Push buttons allow smooth operation of the device.

• The earth resistance value can be read directly from the scale.

• You only need to press the SIMPLIFIED MEAS. button for simplified measurements. No

shorting wire is required since terminals P and C can be shorted internally simply by
pressing this button.

• Battery replacement is easy.

• The carrying case in hard plastic is water-resistant and accommodates all accessories.

2. Specifications

Measuring Ranges

Earth Resistance

10/100/1000

Earth Voltage

30V AC (5K

Ω/V approx.)

Accuracy

Earth Resistance

±5% of full scale

Earth Voltage

±5% of full scale

Measurement System

Measure earth resistance with a CC inverter, 800Hz, ± 2mA
Measure earth voltage through a rectifier, type 5K

Ω/V, ± 40~500Hz

Withstand Voltage

1500V AC for 60 seconds between electrical circuit and the housing.

Self-Check Facility

Press the BATT.CHECK button to test the earth resistance and the
connection with terminals P and C. The OK lamp comes on.

Batteries

8 x 1.5V AA-battery

Dimensions

140 (L) x 140 (W) x 90 (D) mm

Weight ±800g

Advertising