4. Procedure

Inspection conditions

• Viewing distance is approximately 35 ~ 40 cm (for

inspecting adjacent dots and distance between defect

dots, this distance is much closer)

• Viewing angle is normal to the LCD panel (max. 10°

deviation)

• Ambient temperature is 25 ± 5°C

• Ambient humidity is 60 ± 5% RH

• Ambient illuminance is between 300 ~ 500 Lux.

• Input signal timing should be typical value.

A eye

position

B LCD panel


Inspection criteria
Refer to the definitions in §2.
N = number of defects.

defect type

limit

visual

defect

scratch

0.03mm ≤ W ≤ 0.1mm

L ≤ 10mm

N ≤ 4

defect

round 0.3mm

≤ Ø ≤ 1.0mm

N ≤ 5

linear

W ≤ 1.0mm

L ≤ 3.0mm

N ≤ 5

polarizer 0.3mm

≤ Ø ≤ 1.0mm

N ≤ 5

total allowed

N ≤ 10

electrical

defect

single dot

bright* N

≤ 6

dark N

≤ 6

total allowed

N ≤ 9

adjacent dots

2**

≤ 3 pairs

3**

≤ 2 sets

4**

≤ 1 sets

distance between 2 bright dots

≥ 10mm

line defects

N = 0 (not allowed!)

*: visible through a 5% ND (Neutral Density) filter

**: adjacent dots also add to the single dot counter

Note: other defects that may occur e.g. mura are subject to user interpretation and should be

evaluated individually.