5. Coverage pattern


6. PCB description

a. Connection Terminal Description

ALARM

This is the alarm relay output contact of the detector. It is selectable as NC or
NO via the alarm jumper to match the requirements of the protection zone.

DC12V

Connect the positive (+) side to an 8V ~ 16V DC power source, usually from the

alarm control panel. Connect the negative (-) side to the common grounding
point of the control panel.

TAMP NC

If a tamper switch is required, connect these terminals to a 24-hour NC
protection zone in the alarm control panel. The tamper switch contact is closed

with the detector’s front cover secured on the box. The opening of the front
cover at any time will make the contact open and send an immediate alarm

signal to the control panel.