GWP2_v2

PEREL

4

operation is not guaranteed if the gap is too small.

When you set the float switch, make sure that it does not touch the base before the pump switches off. Caution:

risk of dry-running.

Maintenance Guidelines

This submersible pump is an approved high-quality product which is subject to severe final controls. We recommend

regular inspection and maintenance to ensure long equipment life and uninterrupted operation.

Remove the mains plug before all maintenance work.

In the event that the pump is often transported in the course of operation, it should be cleaned out with clear water

after every use.

In case of stationary installation, the function of the floating switch should be checked every 3 months.

All fibrous particles which may have built up inside the pump housing should be removed with a water jet.

Remove deposits on the floater with clear water.

Cleaning the impeller

If excessive deposits collect in the pump case you must dismantle the bottom part of the pump as follows:

Remove the intake cage from the pump case.

Clean the impeller with clear water.

Important! Do not put down or rest the pump on the impeller!

Assemble in reverse order.

Troubleshooting


Problem

Possible Cause

Suggested Solution

Pump does not start

- No mains supply

- Floater does not switch

- Check mains supply

- Bring floater in a higher position

No flow

- Inlet sieve is clogged

- Pressure hose is bent

- Clean inlet sieve water jet

- Reset hose

Pump does not switch off

- Floater cannot sink down

- Place pump properly on shaft

ground

Insufficient flow

- Inlet sieve is clogged

- Reduced pumping capacity by dirty

and abrasive water

- Clean inlet sieve

- Clean pump and replace worn out

parts

Pump switches off after short

operating period

- Thermal cut-out stops pump due to

dirty water

- Water is too hot; thermal cut-out

stops pump

- Remove mains plug, clean pump

and shaft

- Make sure the water temperature

of 35°C is not exceeded

Technical Specifications

Power Supply

max. 230VAC / 50Hz

Power Consumption

max. 550W

Max. Flow Rate

12000l/h

Max. Height

8m

Max. Grain Size

35mm

Power Cord

3 G1.5, 10m

IP Rating

IP68

Use this device with original accessories only. Velleman nv cannot be held responsible in the event of

damage or injury resulted from (incorrect) use of this device. For more info concerning this product, please

visit our website www.perel.eu. The information in this manual is subject to change without prior notice.