Thank you for choosing Perel! Please read the manual thoroughly before
bringing this device into service. If the device was damaged in transit,
don't install or use it and contact your dealer.

The GMK2LAMP contains 4 UV-lamps for use with i.a. the photo-
catalyst mosquito lamp (GMK2).

2. Safety Instructions

Do not use any liquids when cleaning the traps’ internal
parts. Only use the brush that came with the mosquito trap.
Do not stare at the light from the UV-lamp. Permanent eye
damage may occur.

Keep this device away from rain and moisture.

3. Replacing the UV-lamp

Refer to the pictures on page 2 and 3 of this manual.
• Switch off the lamp and disconnect the mains.

• Remove the collecting container (1). To do this, twist the container

counter clockwise and pull (see picture A).

• Remove the 4 screws that keep the lamp holder section (2) and

fan section (3) together (see picture B).

• Pull the lamp holder section (2) and fan section (3) apart. Be

careful not to damage the electrical leads. The cone (4) can also be
removed if necessary (see picture C).

• To remove the UV-lamp, gently turn it a quarter and pull it out of

the sockets.

• Place the new UV lamp in the sockets and turn a quarter to secure

it.

• Re-position the cone (4), guiding the electricity leads through the

gap.

• Put the lamp holder section (2) on top of the fan section (3) with

the screw holes lined up, making sure the electrical leads don’t get
damaged. Push until a click is heard and remount the 4 screws.

• Re-install the collecting container (1). Place it on the fan section

(3) and turn clockwise until it is secured.