Manual Operation

To cook food using a specific entered time and power level.
1. Open oven door and place food in oven. Close door.

2. Press TIME ENTRY pad and enter cooking time.

3. Press POWER LEVEL pad to change power level if desired.

• For a lower microwave power, press pads 1 (for 10%) through 9 (for

90%).

4. If stage cooking is desired, press STAGE pad and repeat steps 2 through 4.

5. Press START pad.
6. At end of cooking cycle oven beeps and shuts off.

DONE

displays.

Programming Pads

1. READY must be in the display. If not, open and close door.

2. Press PROGRAM SAVE pad.

• Programming mode begins.

• Enter Program to Add/Review: displays.

3. Press pad to be programmed or reprogrammed.

• Display will change to review all settings for the pad.

• The pad number that is being programmed displays beside the word

ITEM.

4. Press TIME ENTRY to program amount of cooking time.

• Enter desired cooking time by using numeric key pads.

• Maximum cooking time is 60 minutes.

5. Press POWER LEVEL to program level of microwave power.

• Press numeric key pad for desired level. Press numeric key pad again

to set power level to 100%.

• For a lower microwave power, press pads 1 (for 10%) through 9 (for

90%).

6. Press Quantity pad if different cooking factor is desired.

• Default of CF:80 displays.

• Enter desired cooking factor by using numeric key pads (1 for 10%

through 0 for 100%).

7. Press PROGRAM SAVE to save the program changes.

8. To discard changes, press STOP/RESET.

Mid-Cycle Pause

To add a pause to a programmed

cooking cycle:
1. Press HIDDEN PAD after

entering time or power level.

2. A short beep sounds. This

indicates the program is set for a

mid-cycle pause.

3. Continue programming pad as

desired.

When programmed pad is used,

pause will occur in the middle of total

programmed time. Oven will beep

continuously and

Program Paused

displays until door is open and shut.

To continue cycle, press START pad.

CLEAN FILTER

This oven displays

CLEAN FILTER

at user defined intervals. When the

message displays ACP recommends

cleaning the air filter thoroughly.

Cleaning the air filter will not shut

off the message. The message will

stop displaying automatically after

24 hours. Depending on microwave

use and environmental conditions,

the filter may need to be cleaned

more frequently. Once the frequency

is determined, set the option for the

appropriate time frame.

So...how do I use it?

Preprogrammed

Pads

To cook food using

preprogrammed cooking

sequences.
1. Open oven door and place food

in oven. Close door.

• To add additional servings

press QUANTITY pad.

• Up to eight quantities can be

added.

2. Press desired pad.

3. Oven begins to cook.

4. At end of cooking cycle oven

beeps and shuts off.

DONE

displays.

Oven Clearances

A—For North American (UL/CSA) models, allow at

least 2” (5.1 cm) of clearance around top of oven.

For International (50 Hz) models, allow at least 7”

(17.8 cm) of clearance around top of oven. Proper air

flow around oven cools electrical components. With

restricted air flow, oven may not operate properly and
life of electrical parts is reduced.
B—Allow at least 2

9

/

16

” (6.5 cm) between air

discharge on back of oven and back wall.
C—Allow at least 2” (5.1 cm) around sides of oven.

Refer to Product Safety Manual for Safety Statements

Complete Owner’s Manual available online

Quick Start Reference Guide

Quantity Time Entry Power Level Stage Program Save

Advertising