Xgdc series, 1 ghz horizontal taps, 969 horsham road – Toner Cable XGDC One Port Horizontal Taps User Manual

Page 2

Advertising
background image

969 Horsham Road

l

Horsham, Pennsylvania 19044 USA

l

Phone: 215-675-2053 Fax: 215-675-7543

l

[email protected]

Specifications Subject To Change Without Notice

Rev

06-13

©Toner Cable Equipment, Inc.

XGDC Series

1 GHZ Horizontal Taps

XGDC - Series One Tap Port Model

XGDC-TAP VALUE

7

9

12

16

20

24

27

5-550 MHz

6.5

9

12

16

20

24

27

ATTENUATION

±1.0

±0.8

±0.8

±0.8

±0.8

±0.8

±1.0

IN-TAP (dB)

550-1000 MHz

6.5

9

12

16

20

24

27

±1.2

±1.2

±1.2

±1.2

±1.2

±1.2

±1.2

INSERTION LOSS

5-15 MHz

2.5

1.4

0.9

0.8

0.7

0.7

0.7

IN-OUT

15-40 MHz

2.5

1.4

0.8

0.8

0.7

0.7

0.7

Maximum (dB)

40-550 MHz

2.5

1.4

0.8

0.8

0.7

0.7

0.7

550-1000 MHz

2.7

2.2

1.5

1.2

1.2

1.2

1.2

5-15 MHz

25

22

20

25

25

25

25

RETURN LOSS-IN

15-40 MHz

25

22

25

25

25

25

25

Minimum (dB)

40-550 MHz

20

20

20

20

20

20

20

550-1000 MHz

20

20

20

20

20

20

20

5-15 MHz

22

22

20

25

30

30

30

RETURN LOSS - OUT

15-40 MHz

22

22

28

30

30

30

30

Minimum (dB)

40-550 MHz

20

20

22

22

22

22

22

550-1000 MHz

18

20

20

20

20

20

20

XGDC2 - Series Two Tap Port Model

XGDC-TAP VALUE

7

9

12

16

20

24

27

5-15 MHz

6.5

9

12

16

20

24

27

ATTENUATION

±0.7

±0.7

±0.7

±0.7

±0.6

±0.6

±0.7

15-40 MHz

6.5

9

12

16

20

24

27

±0.7

±0.7

±0.5

±0.7

±0.6

±0.6

±0.6

40-550 MHz

6.5

9

12

16

20

24

27

±0.7

±0.7

±0.7

±1.0

±0.7

±0.7

±0.7

IN-TAP (dB)

550-1000 MHz

6.5

9

12

16

20

24

27

±1.5

±1.5

±1.5

±1.2

±1.2

±1.2

±1.2

INSERTION LOSS

5-15 MHz

3.6

2.5

1.4

1.3

0.7

0.7

0.7

IN-OUT

15-40 MHz

3.6

2.5

1.2

1.0

0.7

0.7

0.7

Maximum (dB)

40-550 MHz

3.6

2.5

1.4

1.0

0.7

0.7

0.7

550-1000 MHz

3.9

2.7

2.1

1.5

1.2

1.2

1.2

5-15 MHz

25

20

20

21

25

25

25

RETURN LOSS-IN

15-40 MHz

25

20

20

22

25

25

25

Minimum (dB)

40-550 MHz

22

20

20

22

22

22

25

550-1000 MHz

22

20

20

20

20

20

20

5-15 MHz

25

20

20

20

25

25

25

RETURN LOSS - OUT

15-40 MHz

30

25

25

30

30

30

30

Minimum (dB)

40-550 MHz

22

20

20

22

22

22

25

550-1000 MHz

22

20

20

20

20

20

22

XGDC3 - Series Three Tap Port Model

XGDC-TAP VALUE

7

9

12

16

20

24

27

5-15 MHz

6.5

9

12

16

20

24

27

ATTENUATION

±0.7

±0.7

±0.7

±1.0

±0.7

±0.6

±0.6

15-40 MHz

6.5

9

12

16

20

24

27

±0.7

±0.7

±0.7

±0.7

±0.7

±0.6

±0.6

40-550 MHz

6.5

9

12

16

20

24

27

±0.7

±0.7

±0.7

±0.7

±0.7

±0.6

±0.6

IN-TAP (dB)

550-1000 MHz

6.5

9

12

16

20

24

27

±0.7

±0.7

±1.2

±1.2

±1.2

±1.2

±1.2

INSERTION LOSS

5-15 MHz

7.0

3.6

2.4

1.2

0.8

0.8

0.8

IN-OUT

15-40 MHz

7.0

3.6

2.4

1.2

0.8

0.8

0.8

Maximum (dB)

40-550 MHz

7.0

3.6

2.4

1.2

0.8

0.8

0.8

550-1000 MHz

7.9

3.9

2.8

2.0

1.4

1.2

1.2

5-15 MHz

24

25

25

25

25

25

25

RETURN LOSS-IN

15-40 MHz

24

25

25

25

25

25

25

Minimum (dB)

40-550 MHz

22

22

22

22

22

22

22

550-1000 MHz

22

20

20

20

20

20

20

5-15 MHz

25

22

22

24

25

25

25

RETURN LOSS - OUT

15-40 MHz

30

28

25

25

28

28

28

Minimum (dB)

40-550 MHz

22

22

22

22

22

22

22

550-1000 MHz

22

20

20

20

20

20

20

Advertising