Setting Desired Power Level:

To set the desired power level from the

normal display mode, press the ‘MENU’

button until ‘PWR’ is displayed, then

press the ‘SELECT’ button.
The current power level setting will be

displayed – press the ‘SELECT’ button to

continue operating at this power level

and return to normal operating mode

(the module will display a ‘SAvED’

message confirming your selection),

or press the ‘MENU’ button to cycle

through power levels ‘STK’ (stock),

‘TOW’ (tow) and ‘SPT’ (sport).
Press ‘SELECT’ when your desired power

level is displayed, and the Bullet module

will instantly make the necessary

corrections to engine fueling, display

a ‘SAvED’ message confirming your

selection, and return to the normal

display mode. If no buttons are pressed

within five (5) seconds, the module will

return to the standard display mode

without saving any changes.

Quick Power Level Changes:

Power levels can also be quickly

changed at any time from the normal

display mode by pressing the ‘SELECT’

button. The currently selected power

level will be displayed – pressing the

‘SELECT’ button again within five (5)

seconds will increase the power level by

one; repeatedly pressing the ‘SELECT’

button will cycle through power levels

‘STK’-‘SPT’.
Pressing the ‘MENU’ button will set

the currently displayed power level as

the new operating level, and display a

‘SAvED’ message before returning to

the normal display mode. If no buttons

are pressed within five (5) seconds,

the module will return to the standard

display mode without saving any

changes.

Setting Desired Maximum

EGT Limit:

To set the desired maximum EGT limit

and alarm level from the normal display

mode, press the ‘MENU’ button until

‘TLMT’ is displayed, then press the

‘SELECT’ button.
The current EGT limit will be displayed,

in degrees Fahrenheit (the default value

is 900 °F). Press the ‘SELECT’ button to

continue operating with this EGT limit

and return to normal operating mode

(the module will display a ‘SAvED’

message confirming your selection),

or press the ‘MENU’ button to cycle

through all available EGT limit options

from 800 °F to 1500 °F, in 50 degree

increments.
Press the ‘SELECT’ button when your

desired maximum EGT limit is displayed,

and the Bullet module will save your

selection, display a ‘SAvED’ message,

and return to the normal display mode.

If no buttons are pressed within five (5)

seconds, the module will return to the

standard display mode without saving

any changes.
The Bullet module will now limit the

measured EGT at or below this value

as much as possible by reducing the

amount of extra fuel that it injects into

the engine. In addition, if the measured

EGT increases past the selected limit,

an alarm will trigger and illuminate the

warning light as well as flashing the

current EGT value on the display.
WARNING: If the Bullet Diesel Tuner

is installed in tandem, or ‘stacked’

with another performance module

that modifies the amount of fuel

injected into the engine, the Bullet

module may not be able to control

EGT within the set limit as it is not

able to control the functions of the

secondary performance module.