Seite 2, Fix gewinde mittelfest – SCT-Germany 9924 FIX-GEWINDE bis M36 mittelfest User Manual

Page 2

Advertising
background image

Prepared according to Annex II of EC Regulation 1907/2006

05.

Fire-fighting measures

5.1

Suitable extinguishing media

Product is not combustible. Adapt to the nature and extent of fire.
5.2

Extinguishing media which shall not be used for safety reasons

High volume water jet
5.3

Special expsure hazards arising from the substance of preparation itself, combustion
products, resulting gases

In case of fire the following can develop:
Oxides of carbon
Oxides of nitrogen
Oxides of sulphur
5.4

Special protective equipment for fire-fighters

In case of fire and/or explosion do not breathe fumes. Protective respirator with independent air supply.
Accordingto size of fire. Full protection, if necessary.
5.5

Further information

Dispose of contaminated extinction water according to official regulations.

Refer to point 13 and for personal protection refer to point 8

06. Accidental release measures

07.

Handling and storage

Refer to point 13. and for personal protection refer to point 8.

6.1

Personal precautionsEnsure sufficient supply of air. Avoid contact with eyes or skin.

Do not carry cleaning cloths soaked in product in trouser pockets.
6.2

Environmental precautions

If leakage occurs, dam up.
Prevent from entering drainage system.
Prevent surface and ground-water infiltration, as well as ground penetration.
6.3

Methods for cleaning up

Collect mechanically and dispose of according to point 13.

7.1

Handling

Tips for safe handling:
See point 6.1
Ensure good ventilation. Avoid contact with eyes or skin. Eating, drinking, smoking, as well as food-storage, is
prohibited in work-room. Observe directions on label and instructions for use.
Use working methods according to operating instructions.
7.2

Storage

Requirments for storage rooms and containers:
Not to be stored in gangways for stair wells. Store product closed and only in original packing. Do not store
with oxidizing agents.
Special storage conditions:
See point 10
Store in a well ventilated place. Store cool.

Printing Date: 01.12.2010

Revision Date: 01.12.2010

Page 2/5

W E L -T W A = W ork p lac e E x po s ur e L im it - Lo ng -t er m e x po s ur e li m it (8 - ho ur T W A (= ti m e w ei g ht ed a v e ra g e) r ef e ren c e p eri od ) E H 4 0. A G W

= " A r beit s plat z g re nz w e rt " ( wo r k plac e lim it v a lue, G e rm a ny) . | W E L- S T E L = W o rk p la c e E xpo s ur e L i m it - S ho rt- t er m e ex po s ur e li m it ( 15 -m i nut e
ref e re nc e p er io d). | B M G V = B i olo gi c a l m o nit o rin g gu id a nc e v al ue E H 4 0. B G W = " B io lo g is c he r G r en z w e rt" ( bio lo gic al li m it v al ue, G e rm a ny ) |
O t he r i nf or m at io n: S e n = C a pa b le o f c a us i ng o c c u pa t io na l as t hm a. S k = C a n be a bs o rb ed t hr o ug h s k in . C arc = C a pa ble o f c a us i ng c an c e r
a nd /o r he ri t ab le g ene t ic da m ag e .
* * = T he e x po s u re li m it f o r t his s ub s t an c e is r ep e al ed t hro ug h t he T R G S 90 0 (G e rm a ny) o f J an ua ry 20 0 6 w it h t he g o a l o f re v i s io n .

08.

Exposure controls/personal protection

Chemical Name

content%: 0,1-<1

WEL-STEL: 50 ppm (250 mg/m³) (WEL,EC)

Other informations: Sk (WEL)

WEL-TWA: 25 ppm (125 mg/m³) (WEL), 20 ppm (100
mg/m³) (EC)

---

Cumene

BMGV: ---

Fix Gewinde mittelfest