B) Add Setpoint to List
Purpose: Ten additional setpoints may be added for calibration. There are 10 factory set-

points at 10% increments starting at 15% ending with 100%. For more accuracy, use this
function to add additional percent points up to 80%.

C) Remove Setpoint from List.
Purpose: Use this function to remove unwanted setpoints from list. If the valve is very line-

ar

D) Edit Catch Values
Purpose: Use to change the actual catch weights in the list. Use to this entry to manually

enter data from a spreadsheet or text file.

E) Edit Sensor values
Purpose: Use to change the actual sensor readings in the list, or manually enter data from

a spreadsheet or text file.

F) ReName Table (6 –char)
Purpose: Used to give each of the 5 tables a unique name (i.e. shot size being used). (S-

70, S-230)

G) Set Flow Limit
Purpose: To change valve calibration. This is the amount the valve will flow when a 10Vdc

signal is sent from the valve.

Valve Capacity:
Purpose: This is the maximum flow the valve can do with the selected shot size.

H) Table Number
Purpose: to provide five separate lookup tables. This allows the user to store calibration

data for five different shot types or sizes.

Function: To sequentially access the five tables select “H”.