INTRODUCTION

The Snap-on TECHANGLE

TM

wrenches digitally display and monitor fastener torque

and angular rotation (turn).

Display Modes:
Torque only—
wrench functions as an adjustable torque wrench.
Torque-angle—wrench functions as an adjustable angle wrench and
simultaneously monitors torque to prevent fastener or wrench overload.

Settings – Adjustable torque and angle settings for fastener installation specifications.
The preset values are programmable from 5% to 100% of full-scale torque and 5 to 360
degrees of rotation. The scrolling display rolls-over at both ends for convenient and
quick setting.

Overload - If the wrench is used beyond 100% torque capacity, the audible tone will
pulse rapidly to warn the user to stop.

Zero/Reset - Automatic self-check, torque zero and angle reset at power-on and any
time the ON/RESET key is pushed. (This is not a calibration check).

FUNCTION DETAILS

To PRESET the wrench, select the UNIT of measure “Nm, ft-lb, in-lb or de-
grees (º)”
desired. Use the UP and DOWN keys to set the torque or angle required. A
torque value must be set prior to setting the angle mode. This provides a “maximum
torque limit” given in some fastener specifications. If no fastener limit is specified then
set the torque to the full scale of the wrench.

In the torque only display mode, the display shows the torque PRESET

value until 5% or more of full scale torque is applied. The display then switches to
TRACK mode showing the applied torque in real time. When applied torque is within
2% of the preset value, the buzzer will sound for 1/2 second and the handle will vibrate
continuously until torque is released. At torque release the display shows the PEAK
value applied flashing for 10 seconds. If torque is re-applied during the 10-seconds the
display will immediately switch to TRACK mode. If any key is pushed during the 10-
seconds the PEAK value will be cleared. If wrench full scale torque is exceeded the
buzzer will pulse and the handle will vibrate until torque is released. Exceeding 125%
of full scale the display will lockup showing “- - - -” and the wrench must be reset by
pushing the ON button.

In the angle display mode, the display shows the torque PRESET value for

one second and then the angle PRESET value. Angle measurement is held in reset
until 5% of F.S. torque is applied. Rotation (turn) is accumulated in angular degrees.
When torque is released, the accumulated torque and angle values will flash alternately
for 10 seconds. The display will continue to accumulate if torque is reapplied within the
10 seconds. This allows time for reverse (ratchet) motion. When the accumulated an-
gle equals the angle preset value, the buzzer will sound for one second and the handle
will vibrate until torque is released. If torque preset (within 2%) is reached first, the
buzzer will pulse and the handle will vibrate until torque is released. As above, after
angle preset or torque preset is reached, and torque is released, the total angle accu-
mulation and the PEAK torque will be displayed alternating for 10 seconds or until any
key is pushed. If angle preset is reached and torque is released, angle accumulation is
reset to zero automatically. This allows moving on to the next fastener immediately.

4

OPERATOR INSTRUCTION

Install three fresh “AA” alkaline cells into the handle of the wrench

.



1 Turn the wrench on by momentarily pushing the
ON/RESET key. The display will return to the mode of
operation and preset values previously set up.

2 To change the mode of operation, TORQUE ONLY or
TORQUE-ANGLE, scroll the selections by momentarily
pushing the UNITS key. The preset values for each
mode will be displayed.

3 Use the UP and DOWN keys to change the preset val-
ues. (Note: Torque is also measured in ANGLE mode
and must be preset prior to adjusting the angle pre-
set). Preset the wrench to full scale if no torque speci-
fication is given.

4 Grasp the center of the handle, (do not pull on the end-
cap) and slowly apply torque to the fastener until the
audible sounder and handle vibration alerts you to
stop.

5 Release torque. Note the peak readings flashing on
the display for 10 seconds or until the ON/RESET key
is pushed to clear the display.


3

BATTERY TORQUE AND/OR ON/RESET INCREMENT
CONDITION ANGLE DISPLAY KEY SET KEY








AUDIBLE TORQUE UNITS DECREMENT
ALERT UNITS KEY SET KEY

Advertising