INSTALLATION DIAGRAM

Specifications - 30 FME-XTR and 30 FME-S-XTR

Rough in dimension: From the floor to the center of bypass approximately 50" for 30 FME-XTR, and
approximately 36-1/2" for a 30 FME-S-XTR
Maximum distance and size for drain line: 50' horizontal, 10" vertical rise, using 1/2" ID drain line
Maximum distance and size for brine line: 15' horizontal (see note) using 1/4" ID poly tubing

NOTE: The horizontal distance for the brine tank can be increasted to 35' if the brine tank is
installed above the unit.

EXAMPLE: Softener installed in the basement and brine tank installed on 1st floor. The brine
tank CANNOT be installed below the bottom of the unit. The drain and brine lines should NOT
be installed with tubing that can collapse. This will cause the unit to malfunction.

CAUTION: Do NOT connect drain line tubing from control valve to overflow fitting/tubing on
brine tank.