Continuous Use

Do not use the flash continuously for more than the number of times stipulated in

the table below, in order to prevent damage to the unit. Once the maximum number

of flashes has been reached, allow the flash to rest for at least 10 minutes before

using it again.

Mode

Maximum Use

ADI, TTL, M(1/1

1/2)

15

M (1/4

1/16)

20

19

Technical Specifications of PZ40X

Guide Number : ISO 100 (m/ft)

English

24mm

(0.9in)

24/78

26/85

28/92

34/111

40/131

Zoom setting

Manual flash

1/1

1/2

1/4

1/8

1/16

Numbers of flashes and Recycling time

Number of flashes

Recycling time

AA Ni-MH Batteries

AA alkaline batteries

Approx 140

Approx 8 sec

Approx 100

Approx 10 sec

Effective Lens focus

Cover 28mm lens or more equivalent to 35mm film

distance camera.

Cover 18mm lens or more equivalent to APS size

digital SLR camera.

Power Zoom

Automatic setting / Signal from camera

Manual setting / Pressing the Zoom Button

AF illuminator Range

1-5m (22 – 16in) (Lens F2/50mm)

Operating temperature

0˚C - 40˚C (32˚F - 104˚F)

Dimensions

93(H)X63(W)X90(L)mm (3.6 x 2.4 x 3.5 in)

Weight

200g (7.0 oz)

Note. The design and specifications of this product are subject to change without prior notice.

28mm

(1.1in)

35mm

(1.4in)

50mm

(2.0in)

80mm

(3.1in)

17/56

18/59

20/66

24/78

28/92

12/40

13/43

14/46

17/56

20/66

8/26

9/30

10/33

12/40

14/46

6/20

6/20

7/23

8/26

10/33

* Numbers of flashes: Measured with new batteries that are within 3 months from their date of

production, flashed every 30 seconds continuously and recycled to the point at which the Ready Light

takes 30 seconds to come on after the last flash.

Recycling time: The time to activate the Ready Light under the above conditions.