Specifications and performances – Sunpak auto 16R pro User Manual

Page 11

Advertising
background image

23

Notes for Successive Firing

To prevent degradation due to overheating that may result from successive fi ring, it
is recommended to limit the number of fl ashes as shown in the following table and
pause fi ring for more than 10 minutes after the limit is reached.

Mode

Max. number of successive flashes

Auto, Manual (1/1 – 1/2)

15 times

Manual (1/4 – 1/256)

20 times

Specifications and Performances

Guide Numbers (ISO 100, m)

Auto Mode Working
Range (m/ft)

Manual mode

1/1

16

f-value

Range

1/2

11

F/2

8 m (26 ft)

1/4

8

F/4

4 m (13 ft)

1/8

5.6

F/8

2 m (6.6 ft)

1/16

4

F/16

1 m (3.3 ft)

1/32

2.8

1/64

2

1/128

1.4

1/256

1

Initial Number of Flashes and Recycling Time

Number of flashes (Full power)

Recycling time (Full power)

“AA”-size alkaline batteries x 4

Approx. 100 times

Approx. 8 sec.

“AA”-size NiMH batteries x 4

Approx. 180 times

Approx. 6 sec,

z Number of flashes: Measured under the normal temperature, with new batteries that are within 3

months from their date of production, flashed every 30 seconds continuously and recycled to the point
at which the Ready lamp takes 30 seconds to come on after the last flash.

z Recycling time: The minimum time taken to activate the Ready lamp after firing under the above

conditions.

z Remove Batteries :After using auto 16R pro ,please remove batteries from the flash.If you leave

batteries in the flash, it may be damaged due to leak of battery liquid.

Operating temperature

0 to 40°C (32 to 104°F)

Dimensions

Power supply section: 133(H) x 74(W) x 82(D) mm

Light emitting section: 121(H) x 121(W) x 33(D) mm

Weight

Power supply section: 260 grams (9.17 oz) excl. batteries

Light emitting section: 145 grams (5.11 oz)

z The design and specifications of this product are subject to change without prior notice.