Turbosmart BOV ADAPTERS - Nissan 200SX User Manual

Page 2

Advertising
background image

200SX S14 & S15 BLOW-OFF VALVE ADAPTOR INSTRUCTIONS

Head Office: Turbosmart Pty Limited, PO Box 264 Croydon, NSW, 2132 Australia

Ph: +61(2) 9798 2866

Fax: +61 (2) 9798 2826

Email:

[email protected]

USA Office: Turbosmart USA, 1185 Park Center Drive, Suite Q, Vista CA 92081 USA

Ph: (760) 727 7610

Fax: (760) 727 7963

Email:

[email protected]

PART NUMBER
FG-ADM-200SX


Step 3. Loosen the bottom hose clamp on the factory
intercooler pipe. Remove the factory intercooler pipe.

Step 4. Fit the Silicon hose coupler over the top of the
200SX adaptor and connect the two ends onto the
factory pipes with the BOV mounting pointing towards
the rear of the engine.


Step 5. Use two of the supplied 60mm hose clamps
to secure the Silicon hose coupler over the turbo
outlet and the 200SX Adaptor pipe. Tighten the hose
clamps with a 7mm socket or screwdriver.

Step 6. Use the remaining 60mm hose clamp supplied to
secure the intercooler pipe to the 200SX Adaptor pipe.
Tighten the hose clamp with a 7mm socket or
screwdriver.


Step 7. Locate the Factory BOV under the fuse box
on the left hand side of the engine bay. Disconnect
the factory vacuum/boost line.


Step 8. Take the pre-assembled 5mm ID Silicon hose &
reducer and connect the assembly as shown below.

BOV mount

pointing

towards the

rear of the

engine

Silicon Hose

Coupler

Fuse Box

Factory

Vacuum/boost Line

Factory BOV

Connect 6mm

reducer to factory

boost/vacuum line

1500mm

Connect this end of

5mm ID Silicon hose

to Turbosmart BOV

Advertising