Turbosmart WASTEGATES – EXTERNAL - Comp-Gate40 (with locking ring) User Manual

Page 4

Advertising
background image

www.TURBOSMARTONLINE.com

4

IMPORTANT NOTES ON SETTING THE WASTEGATE SPRING PRESSURE

A stiffer spring should only be used when necessary. The Comp-Gate40 allows for different combinations of spring pressures. All
springs that are adaptable with the Comp-Gate40 are shown in the table below. The tuner can use combinations of up to 3 springs to
achieve the following base boost pressures. To aid in the identification of these springs they are supplied colour coded. If this colour
coding is not clear please use the dimensions in the following table to identity the wastegate spring. Please see the following detailed
instructions on setting your Comp-Gate40’s spring pressure. The springs chosen should be rated to the lowest boost level desired.

Pressure rating

3 PSI Inner

5 PSI Inner

7 PSI Middle

11 PSI Middle

10 PSI Outer

7 PSI Outer

Part number

TS-0505-2001

TS-0505-2002

TS-0505-2003

TS-0505-2004

TS-0505-2005

TS-0505-2006

Colour

BRN/BLK

BRN/GRY

BRN/PUR

BRN/RED

BRN/BLU

BRN/PNK

Dimensions

29mm OD,

32mm Length

29mm OD,

36mm Length

36.5 OD, 43mm

Length

36.5 OD,

52mm Length

44mm OD, 68mm

Length

44mm OD,

57mm Length

Desired Boost

Pressure

PSI

BAR

KPa

3

0.207

20.68

5

0.345

34.47

7

0.483

48.26

10

0.69

68.95

11

0.76

75.84

12

0.827

82.74

13

0.89

89.6

14

0.965

96.53

15

1.03

103.4

16

1.1

110

17

1.172

117.2

19

1.31

131

20

1.38

138

21

1.45

145

22

1.517

151.7

23

1.59

159

24

1.655

165.5

26

1.793

179.3


Advertising