Peerless Lighting EGRW9 - T5_T5HO User Manual

Lightedge rectangular wall softshine or grateoptic, Indirect t5/t5ho, Wall mount

Advertising
background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

EGRW9 1-T5 GTO

EGRW9 2-T5 GTO

EGRW9 1-T5 OPD

EGRW9 2-T5 OPD

EGRW9 1-T5 GTO

EGRW9 2-T5 GTO

EGRW9 1-T5 OPD

EGRW9 2-T5 OPD

EGRW9 1-T5 GTO

EGRW9 2-T5 GTO

EGRW9 1-T5 OPD

EGRW9 2-T5 OPD

EGRW9 1-T5 GTO

EGRW9 2-T5 GTO

EGRW9 1-T5 OPD

EGRW9 2-T5 OPD

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Lightedge” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect T5/T5HO

EGRW9  Lightedge Rectangular Wall Softshine or GrateOptic

Lightedge Rectangular

Wall Softshine or GrateOptic

Indirect T5/T5HO

Examples:

EGRW9 1 54T5HO SSH 40FT R12 120 GEB10 2SE EL SCT LP835 C100 — EGRW9 2 54T5HO SSH 12FT R12 277 GEB10 DCT L/LP C100

Wall Mount

EGRW9

Construction

Housing and end caps are extruded aluminum

forming an 7

1

2

” x 1

1

2

” rectangular profile.

Reflectors

Die-formed white painted reflector (nominal

reflectance 90%) and hammertone specular

aluminum. Prismatic acrylic kicker lens.

Shielding

Crenulated GrateOptic® diffuser or Softshine® high

performance lens.

Finish

Satin anodized standard. Custom colors available,

consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’, 8’ and 12’ lengths in a single section. For total

luminaire length add 4” for each end cap. Using

internal joiners, 4’, 8’ and 12’ sections can be joined

to form longer-length luminaires.

__________ __________

__________

_________

_________

__________

__________ __________

__________

__________

Lumi-

naire

EGRW9

# of Lamps

in Cross

Section

1

2

Lamp Type

28T5

1

28W T5

54T5HO 54W T5HO

Shielding

GTO GrateOptic

SSH Softshine

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

2

Ballast Type

GEB10

<10% THD Electronic

ADEZ

1,2

Advance Mark 10 dim

DMHL3D

1

Lutron Hi-Lume dim

OSDIM

1,2

Osram 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

Emergency Type

3

(Blank) None

EC

Emergency circuit

EL

1

Emergency battery

pack

EN

1

Emergency battery

pack w/night light

circuit

______________

________________

______________

_________________________________

Switching

SCT

Single circuit

DCT Dual circuit

Lamp Color

L/LP No lamp

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI

Available with T5 only:

LP830P 3000K 80+ CRI Premier

LP835P 3500K 80+ CRI Premier

LP841P 4100K 80+ CRI Premier
Reference

Lamp Chart

on website or

consult factory for other options.

Finish

C041 White white (low gloss)

C100 Satin anodized finish

C099 Custom finish

Options

DL

Damp location label

DU

Dust cover

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared neutral

ELS2 Emergency through wiring w/single feed, separate neutrals

EXT 3” extended mount (consult factory)

GLR Fusing (fast blow)

GMF Fusing (slow blow)

Notes:

1 Not available in 347V

2 Not available with 28T5 lamps

3 Emergency type is installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified

EGRW9 - 1 - GTO

EGRW9 - 2 - GTO

EGRW9 - 1 - SSH

EGRW9 - 2 - SSH

7

1

2

7

1

2

7

1

2

7

1

2

1

1

2

1

1

2

1

1

2

1

1

2

SSH

GTO

Advertising