Peerless Lighting IAM8 - T5_T5HO User Manual

Icetray angular i/d, Indirect-direct t5/t5ho, Suspended

Advertising
background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

IAM82 T5

IAM81 T5

IAM84 T5

IAM83 T5

IAM82 T5

IAM81 T5

IAM84 T5

IAM83 T5

IAM82 T5

IAM81 T5

IAM84 T5

IAM83 T5

IAM82 T5

IAM81 T5

IAM84 T5

IAM83 T5

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “IceTray” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect-Direct T5/T5HO

IAM8  IceTray Angular I/D

Suspended

IAM8

Examples:

IAM8 2 54T5HO 20FT R8 120 GEB10 SCT LP835 F1/18 C100 — IAM8 4 54T5HO 24FT R8 277 GEB10 1SE EN DCT LP841 F1/24 C041

IceTray Angular I/D

Indirect-Direct T5/T5HO

IAM8 - 1

3

1

2

9

3

4

IAM8 - 4

3

1

2

9

3

4

IAM8 - 3

3

1

2

9

3

4

IAM8 - 2

3

1

2

9

3

4

Construction

Nominal 10” x 3” with extruded aluminum spine

and nominal four 4’ one-piece aluminum

baffle assemblies. Steel and die-cast aluminum

sculptured end cap.

Reflectors

White painted center reflector is integrated with

the baffle (nominal 90% reflectance). Perforated

side reflector/shield. One-lamp uses hammertone

center reflector.

Shielding

Straight blade baffles with perforated side reflector/

shield. Optional opal acrylic diffuser overlay

(recommended with T5HO lamps).

Finish

Satin anodized or white polyester powder paint.

Satin anodized finish consists of satin anodized

housing, clear-coated aluminum baffles and end

caps painted C110 to match. Note that clear coated

aluminum baffles retain the slight imperfections

and characteristics of the raw aluminum source

material. Custom colors available, consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’, 8’, and 12’ lengths in a single section for exact

suspension spacing of 4’, 8’ and 12’. For total

luminaire length, add 1

3

8

” for each end cap. Using

internal joiners 4’, 8’, and 12’ sections can be joined

to form longer rows.

__________

__________

__________

__________

__________

_________

__________

__________ __________

__________

Luminaire

IAM8

# of

Lamps in

Cross

Section

1

2

3

4

Lamp Type

28T5 28W T5

54T5HO 54W T5HO

Distribution

1

(Blank) 85% up,

15% down

(Standard)

40/60

2

40% up,

60% down

5/95

2,3

5% up,

95% down

Shielding

(Blank) No opal diffuser

OPD Opal diffuser

(Recommended

with T5HO;

not available

with 5/95

distribution)

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

4

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD Electronic

ADEZ

5,6

Advance Mark 10 dim

DMHL3D

5

Lutron Hi-Lume dim

OSDIM

5,6

Osram 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

______________

________________

________________

______________

______________

______________

_________________________________

Emergency Type

7

(Blank) None

EC Emergency

circuit

EL

5

Emergency

battery pack

EN

5

Emergency

battery pack

w/night light

circuit

Switching

SCT

Single circuit

DCT Dual circuit

Lamp Color

L/LP No lamp

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI

Available with T5 only:

LP830P 3000K 80+ CRI

Premier

LP835P 3500K 80+ CRI

Premier

LP841P 4100K 80+ CRI

Premier

Reference

Lamp Chart

on

website or consult factory

for other options.

Mounting Type /

F1/

T-bar ceiling (universal

mounting bracket)

F1A/ T-bar ceiling (UMB with

integrated J-box)

F2/

Hard ceiling (horizontal

J-box)

F3/

Rigid stem

Overall

Suspension

12 12”

15 15”

18 18”

21 21”

24 24”

XX XX”
Overall

suspension is

measured from

ceiling to bottom

of luminaire.

Finish

C041 White white (low

gloss)

C100 Satin anodized

finish

C099 Custom finish

Options

ACG

Adjustable cable grippers

BLK

Black cord, cord manager and canopy (not available

with F3 mtg)

CP

Chicago plenum (available with F1A only)

DL

Damp location label

DU

8

Dust cover

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared

neutral

ELS2

Emergency through wiring w/single feed, separate

neutrals

GLR

Fusing (fast blow)

GMF

Fusing (slow blow)

MCS

Matching feed canopy at support

NEPP5D nLight enabled control module per row/zone

NYC

New York City code

OJB

Offset junction box

SLP

Sloped ceiling (for 10-45°, must be specified with F2,

ACG and OJB options)

XXXX Integrated sensor; choose options and obtain code on

page 2

Notes:

1 Percentages with OPD shielding (except 5/95)

2 Not available with 1-lamp

3 Not available with OPD

4 Not available with 4-lamps

5 Not available in 347V

6 Not available with 28T5 lamps

7 Emergency type is installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified

8 Not available with 5/95 or 40/60

Advertising