Peerless Lighting CRW1 - T8 User Manual

Cerra wall, Indirect indirect t8, Wall mount

Advertising
background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Cerra” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect T8

Examples:

CRW1 1 32 WHR 40FT R12 277 GEB10 SCT LP835 C210 SCEP — CRW1 2 32 SPR 32FT R8 277 GEB10 1SE EL DCT LP835 C110

Wall Mount

CRW1

Cerra Wall

Indirect

Indirect T8

Construction

Housing is formed from one-piece cold-rolled

steel. Flat end plate standard. Sculptured die-cast

aluminum end cap is optional.

Reflectors

Die-formed highly reflective white or specular

reflector.

Finish

Fine-textured, white or aluminum polyester powder

paint. Custom colors available, consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

Nominal 4’, 8’, and 12’ sections form row lengths.

For total run length, add

1

16

” for each flat end plate

or 4” for each sculptured end cap. For longer run

lengths, sections are attached using internal joiners.

Consult factory for 2’ and 3’ individual sections.

Optional sculptured end cap

CRW1 - 1

CRW1 - 2

7

5

8

2

11

16

7

5

8

2

11

16

__________

__________

__________

__________

_________

__________

__________ __________

__________

Luminaire

CRW1

# of

Lamps in

Cross

Section

1

2

Lamp Type

32

32W T8

Reflector

WHR White

Reflector

(Standard)

SPR Specular

Reflector

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD Electronic

DMHL3D

1

Lutron Hi-Lume dim

OS5C

Osram Line or 0-10V

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

______________

__________

________________

______________

_________________________________

Emergency Type

2

(Blank) None

EC

Emergency circuit

EL

Emergency battery pack

EN

Emergency battery pack

w/night light circuit

Switching

SCT

Single circuit

DCT Dual circuit

Lamp Color

L/LP No lamp

L/LPE No lamp. Wired for energy

saving lamps.

LP830 3000K 80+ CRI

LP835 3500K 80+ CRI

LP841 4100K 80+ CRI
Reference

Lamp Chart

on website or

consult factory for other options.

Finish

C110 Painted aluminum (low gloss)

C210 White white (fine-textured low gloss)

C099 Custom finish

Options

DL

Damp location label

DU

Dust cover

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared neutral

ELS2 Emergency through wiring w/single feed, separate neutrals

GLR Fusing (fast blow)

GMF Fusing (slow blow)

SCEP Sculptured end cap

Notes:

1 Not available in 347V

2 EL and EC are installed in last 4’ of luminaire sections and are not available

concurrently with each other. Separate feed required for each EL or EC unless

ELH is specified

CRW1  Cerra Wall

Advertising