Peerless Lighting PRM3 - T8 User Manual

Prima lightvent, Indirect t8, Suspended

Advertising
background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Prima” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect T8

PRM3  Prima Lightvent

Examples:

PRM3 2 32 WHR 40FT R12 120 GEB10 2SE EL SCT LP835 F1/24 C110 — PRM3 3 32 SPR 12FT R8 277 GEB10 DCT LP835 F2/15 C518 GLR

Notes:

1 Not available in 347V

2 EL and EC are installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified

Construction

9” x 3” one-piece cold-rolled steel housing with flat

end plate.

Reflectors

Die-formed highly reflective white or specular

reflector.

Shielding

Die-punched perforated hole pattern.

Finish

Fine-textured, white paint or silver paint to match

anodized aluminium are standard. Custom colors

available, consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’, 8’, and 12’ lengths in a single section for exact

suspension spacing of 4’, 8’, and 12’. For total

luminaire length add

1

16

” for each end cap. Using

internal joiners, 4’, 8’, and 12’ sections can be joined

to form longer-length luminaires.

Prima Lightvent

Indirect T8

Suspended

PRM3

PRM3- 2

PRM3 - 3

9”

3”

9”

3”

PRM3 - 4

9”

3”

__________

__________

__________

__________

_________

__________

__________ __________

__________

__________

Luminaire

PRM3

# of

Lamps in

Cross

Section

2

3

4

Lamp Type

32

32W T8

Reflector

WHR White

Reflector

(Standard)

SPR Specular

Reflector

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD Electronic

ADEZ

1

Advance Mark 10 dim

DMHL3D

1

Lutron Hi-Lume dim

ADZT

1

Advance Mark 7 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

Emergency Type

2

(Blank) None

EC

Emergency circuit

EL

1

Emergency battery pack

EN

1

Emergency battery pack

w/night light circuit

______________

________________

______________

______________

______________

_________________________________

Switching

SCT

Single circuit

DCT Dual circuit

Lamp Color

L/LP No lamp

L/LPE No lamp. Wired

for energy saving

lamps.

LP830 3000K 80+ CRI

LP835 3500K 80+ CRI

LP841 4100K 80+ CRI
Reference

Lamp Chart

on

website or consult factory

for other options.

Mounting Type /

F1/

T-bar ceiling (universal

mounting bracket)

F1A/ T-bar ceiling (UMB with

integrated J-box)

F2/

Hard ceiling (horizontal

J-box)

F3/

Rigid stem

Overall Suspension

12 12”

15 15”

18 18”

21 21”

24 24”

XX XX”
Overall suspension is

measured from ceiling to

bottom of luminaire.

Finish

C110 Painted aluminum

(low gloss)

C518 White (fine-

textured low

gloss)

C099 Custom finish

Options

ACG

Adjustable cable grippers

BLK

Black cord, cord manager and canopy (not available with F3)

CP

Chicago plenum (available with F1A only)

DL

Damp location label

DU

Dust cover

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared neutral

ELS2

Emergency through wiring w/single feed, separate neutrals

GLR

Fusing (fast blow)

GMF

Fusing (slow blow)

MCS

Matching feed canopy at support

NEPP5D nLight enabled control module per row/zone

NYC

New York City code

OJB

Offset junction box

SLP

Sloped ceiling (for 10-45°, must be specified with F2, ACG and

OJB options)

XXXX Integrated sensor; choose options and obtain code on page 2

Advertising