Peerless Lighting BRM4 - T5_T5HO User Manual

Bruno i/d, Indirect-direct t5/t5ho, Suspended

Advertising
background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ _____________________

BRM4 1 T5/T5HO WHR

BRM4 3 T5/T5HO WHR

BRM4 2 T5/T5HO WHR

BRM4 1 T5/T5HO WHR

BRM4 3 T5/T5HO WHR

BRM4 2 T5/T5HO WHR

BRM4 1 T5/T5HO WHR

BRM4 3 T5/T5HO WHR

BRM4 2 T5/T5HO WHR

Type:

________________________

Project:

______________________


1

© 2013 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Peerless Bruno” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect-Direct T5/T5HO

BRM4  Bruno I/D

Examples:

BRM4 2 28T5 SPR SSB 40FT R8 277 GEB10 DCT LP835 F1/18 C210 SCEP — BRM4 3 54T5HO SPR WPB 32FT R8 277 GEB10 1SE EL DCT LP835 F1/21 C110

Construction

Nominal 8

1

4

” x 1

3

4

” rectangular housing is formed

from cold-rolled steel. Die-cast end caps are

mechanically attached with no exposed fasteners.

Reflectors

Die-formed specular reflector with 95% reflectance.

Shielding /Baffle

Choose one of four parabolic baffle options: semi-

specular, white painted, semi-specular perforated

blade or white painted, perforated blade. Each

available with optional acrylic opal overlay.

Finish

Fine textured white polyester powder

paint is standard. Consult factory for special

finish requirements.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’

3

8

”, 8’ and 12’ lengths in a single section for

nominal support spacing at 4’, 8’ and 12’. For total

luminaire length, add

5

8

” for each flat end cap

and 4” for each sculptured end cap. Using internal

joiners, 4’, 8’ and 12’ sections can be joined to form

longer rows.

Suspended

BRM4

8

1

4

BRM4 - 1

BRM4 - 2

BRM4 - 3

1

3

4

1

2

8

1

4

1

3

4

1

2

8

1

4

1

3

4

1

2

________

_______

_______

__________

__________

__________

__________

_________

__________

_______

__________

Luminaire

BRM4

# of

Lamps

in

Cross

Section

1

2

3

Lamp Type

28T5

1

28W T5

54T5HO 54W T5HO

Reflector

SPR Specular

reflector

Distribution

(Blank) Standard

65/35

20/80

2

20% up,

80% down

40/60

2

40% up,

60% down

0/100

2

0% up,

100% down

CLI

3

Center lamp

isolater

Shielding

(Blank)

OPD Opal

overlay

Baffle

SSB Semi-specular

baffle

WPB White painted

baffle

SSP Semi-specular

perforated

blade baffle

WPP White painted

perforated

blade baffle

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD

Electronic

ADEZ

1,4

Advance Mark

10 dim

DMHL3D

1

Lutron Hi-Lume

dim

OSDIM

1,4

Osram 0-10V

dim

Reference

Ballast Wizard

on

website or consult factory for

other options.

_______

_______

_______

________________

______________

______________

______________

_________________________________

# of

Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

Emergency

Type

5

(Blank) None

EC Emergency

circuit

EL

1

Emergency

battery

pack

EN

1

Emergency

battery

pack

w/night

light

circuit

Switching

SCT Single

circuit

DCT Dual

circuit

Lamp Color

L/LP No lamp

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI

Available with T5 only:

LP830P 3000K 80+

CRI Premier

LP835P 3500K 80+

CRI Premier

LP841P 4100K 80+

CRI Premier

Reference

Lamp Chart

on

website or consult factory

for other options.

Mounting Type /

F1/

T-bar ceiling

(universal

mounting

bracket)

F1A/ T-bar ceiling

(UMB with

integrated

J-box)

F2/

Hard ceiling

(horizontal

J-box)

F3/

Rigid stem

Overall

Suspension

12 12”

15 15”

18 18”

21 21”

24 24”

XX XX”
Overall

suspension

is measured

from ceiling

to bottom of

luminaire.

Finish

C110 Painted

aluminum

(low

gloss)

C210 White

white

(fine-

textured

low gloss)

C099 Custom

finish

Options

ACG

Adjustable cable grippers

BLK

Black cord, cord manager and canopy (not available with F3)

CP

Chicago plenum (available with F1A only)

DL

Damp location label

DU

6

Dust cover

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared neutral

ELS2

Emergency through wiring w/single feed, separate neutrals

GLR

Fusing (fast blow)

GMF

Fusing (slow blow)

MCS

Matching feed canopy at support

NEPP5D nLight enabled control module per row/zone

NYC

New York City code

OJB

Offset junction box

SCEP

Sculptured end cap

SLP

Sloped ceiling (for 10-45°, must be specified with F2, ACG and

OJB options)

XXXX Integrated sensor; choose options and obtain code on page 2

Notes:

1 Not available in 347V

2 Nominal distribution, refer to photometric tests for exact

distribution. Not available with DU option

3 Available with 3-lamp cross section luminaires only

4 Not available with 28T5 lamps

5 Emergency type is installed in last 4’ of luminaire sections

Separate feed required unless ELS or ELS2 is specified.

6 Not available with 3-lamp T5HO cross section

SCEP Option

Bruno I/D

Indirect-Direct T5/T5HO

Advertising