Peerless Lighting SPM9 - T8 User Manual

Staple lens i/d, Indirect-direct t8, Suspended

Advertising
background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ _____________________

1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect-Direct T8

SPM9  Staple Lens I/D

Type:

________________________

Project:

______________________


Suspended

SPM9

Staple Lens I/D

Indirect-Direct T8

Examples:

SPM9 2 32 WHR 40FT R12 277 GEB10 DCT LP835 F1/24 C032  — SPM9 3 32 WHR 32FT R8 277 GEB10 1SE EL DCT LP835 F1/24 C032

SPM9 - 1

SPM9 - 2

SPM9 - 3

8

1

2

8

1

2

8

1

2

2

3

8

2

3

8

2

3

8

__________

__________

__________

__________

__________

_________

__________

__________

__________

Luminaire

SPM9

# of Lamps

in Cross

Section

1

2

3

Lamp Type

32 T8

Distribution (nominal)

(Blank) 65% up, 35% down

standard

40/60

1

40% up, 60% down

20/80

1

20% up, 80% down

0/100

1

100% down

CLI

2

Center lamp isolator

Reflector

WHR White

Reflector

(Standard)

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

Ballast Type

GEB10

<10% THD Electronic

DMHL3D

3

Lutron Hi-Lume dim

OS5C

3

Reference

Ballast Wizard

on website

or consult factory for other options.

______________ ________________

___________

________________

______________

______________

______________

_________________________________

# of

Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

Emergency Type

4

(Blank) None

EC Emergency

circuit

EL

3

Emergency

battery pack

EN

3

Emergency

battery pack

w/night light

circuit

Switching

SCT Single

circuit

DCT Dual

circuit

Lamp Color

L/LP No lamp

L/LPE No lamp. Wired

for energy

saving lamps.

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI
Reference

Lamp Chart

on

website or consult factory

for other options.

Mounting Type /

F1/

T-bar ceiling

(universal mounting

bracket)

F1A/ T-bar ceiling (UMB

with integrated J-box)

F2/

Hard ceiling

(horizontal J-box)

Overall

Suspension

5

24

24”

48

48”

72

72”

96

96”

XX

XX”

Overall suspension

is measured from

ceiling to bottom

of luminaire.

Finish

C032 White white

(high gloss)

C099 Custom finish

Options

CP

Chicago plenum (available with F1A only)

DL

Damp location label

DU

Dust cover

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed,

shared neutral

ELS2

Emergency through wiring w/single feed,

separate neutrals

GLR

Fusing (fast blow)

GMF

Fusing (slow blow)

IND

Individual luminaire (factory installed

end caps and power cord, hanging

hardware in box)

MCS

Matching feed canopy at support

NEPP5D nLight enabled control module

per row/zone

NYC

New York City code

OJB

Offset junction box

SLP

Sloped ceiling (for 10-45°, must be

specified with F2 and OJB options)

XXXX Integrated sensor; choose options and

obtain code on page 2

Construction

Nominal 8

1

2

” x 2

3

8

” rectangular housing is

formed from cold-rolled steel. Die-cast aluminum

end caps are mechanically attached with no

exposed fasteners.

Reflectors/ Shielding

Formed, pre-finished white reflector standard.

Acrylic lens shielding.

Finish

White gloss powder paint comes standard.

Custom colors available, consult factory.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’, 8’ and 12’ lengths in a single section for nominal

suspension spacing of 4’, 8’ and 12’. For total

luminaire length, add 1

1

8

” for each end cap. Using

internal joiners, 4’, 8’ and 12’ sections can be joined

to form longer length luminaires.

Installation Features

Y-hangers with adjustable cables come standard

to simplify luminaire leveling across the width

and length. Individual 4’, 8’ and 12’ luminaires

can be ordered with end caps and power cords

pre-installed and hanging hardware included in the

luminaire packaging to reduce overall installation

time (option IND).

Packaging

Recycled cardboard box, folded cardboard cradles

and kraft tape. Biodegradable protective luminaire bag.

Notes:

1 Nominal distribution, refer to photometric test for

exact distribution

2 Available with 3-lamp cross section only

3 Not available in 347V

4 EL and EC are installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified

5 Adjustable cable gripper comes standard

Advertising